WATER SUPPLY
(Cold Water Only)
CAUTION
When connecting the water inlet to the water
supply mains, local regulations of your water
company must be observed. In some areas
the unit must not be connected directly to the
public drinking water supply. This is to ensure
that there is no feedback of chemicals into the
water supply. Direct connection via a receiver
tank or backflow preventer, for example, is
permitted.
Dirt in the feed water will damage the unit. To
avoid this risk, we recommend fitting a water
filter.
Garden hose must be at least 3/4 inch in
diameter.
Flow rate of water supply must not fall
below 3,0 GPM (HD 2.3/15 C Ed), 4,0 GPM
(HD 3.0/20 C Ea) (gallons per minute).
Flow rate can be determined by running the
water for one minute into an empty 5-gallon
container.
The water supply temperature must not
exceed 140°F/60°C.
Never use the pressure washer to draw in
water contaminated with solvents, e.g.
paint thinners, gasoline, oil, etc.
Always prevent debris from being drawn
into the unit by using a clean water source.
CANADA:
WARNING
Do not spray electrical apparatus and wiring.
Do not use with flammable liquids and toxic
chemicals.
Injection hazard: equipment can cause
serious injury if the spray penetrates the skin.
do not point the gun at anyone or any part of
the body. In case of penetration seek medical
aid immediately.
This system is capable of producing
10400 kPa /1500 PSI (HD 2.3/15 C Ed),
13000 kPa /2000 PSI (HD 3.0/20 C Ea) to
avoid rupture and injury, do not operate this
pump with components rated less than
10400 kPa /1500 PSI (HD 2.3/15 C Ed),
13000 kPa /2000 PSI (HD 3.0/20 C Ea)
working pressure (including but not limited to
spray guns, hose and hose connections).
Before servicing, cleaning or removing any
parts, shut off power and relieve pressure.
Extension Cords
Use only 3-wire extention cords that have
3-prong grounding-type plugs and 3-pole
cord connectors that accept the plug from
the product.
Up to 100 ft = 12/3 AWG;
Use only extension cords that are intended
for outdoor use. These extension cords are
identified by the marking "Acceptable for
use with outdoor appliances; store indoors
while not in use."
Use only extension cords having an
electrical rating not less than the rating of
the product.
Do not use damaged extension cords.
Examine extension cord before using and
replace if damaged.
Do not abuse extension cord and do not
yank on any cord to disconnect.
Keep cord away from heat and sharp
edges.
Always disconnect the extension cord from
the receptacle before disconnecting the
product from the extension cord.
If you are using an extension cord, it should
always be completely unwound from the
cable drum.
WARNING
To reduce the risc of electrocution, keep all
connections dry and off the ground. Do not
touch plug with wet hands.
SAVE THESE
INSTRUCTIONS!!
English