Technical data
General data and operating conditions
Mounting conditions
Mounting place
Mounting position
Mounting clearances
Above/below
To the sides
Connection conditions for DC power supply module
AC mains operation
DC-bus operation
Supply systems
TT
TN
With earthed phase
IT

Operating conditions

Environmental conditions
Climate
Storage
Transport
Operation
Site altitude
Pollution
Vibration resistance
Transport
Operation
40
IEC/EN 60721-3-1
IEC/EN 60721-3-2
IEC/EN 60721-3-3
EN 61800-5-1
2
(9.81 m/s
= 1 g)
IEC/EN 60721-3-2
EN 61800-2
Germanischer Lloyd
EN 50178
In the control cabinet
Vertical
≥ 80 mm / ≥ 120 mm
Side-by-side mounting without
any clearance
Direct connection
Direct connection of axis modules via terminals or busbar
system
More information can be found in the Hardware Manual,
chapter "DC-bus operation".
Operation permitted without restrictions.
Operation permitted if additional measures are taken:
The protection of persons according to EN 61800-5-1
requires the supplementary insulation of control cables.
The measures described for IT systems have to be taken.
Operation permitted without restrictions.
1K3 (-25 ... +60 °C)
2K3 (-25 ... +70 °C)
3K3 (-10 ... +55 °C)
Current derating at +45 ... +55 °C: 2.5 %/°C
0 ... 4000 m amsl
1000 ... 4000 m amsl: current derating of 5 %/1000 m
Pollution degree 2
2M2
2 ... 9 Hz: amplitude 3.5 mm
10 ... 200 Hz: acceleration resistant up to 10 m/s
200 ... 500 Hz: acceleration resistant up to 15 m/s
5 ... 13.2 Hz: amplitude ±1 mm
13.2 ... 100 Hz: acceleration resistant up to 0.7 g
10 ... 57 Hz: amplitude 0.075 mm
57 ... 150 Hz: acceleration resistant up to 10 m/s
Observe the device-related
notes on mounting.
2
2
2
EDK94PNE245 DE/EN/FR/ES/IT 1.0