1975E-400A
Control Panel
There must be an independent air supply to
the Control Panel (no tees or splices) from a
main line. This line should be able to
maintain 4 CFM of air at 80 PSI. If the
Backlatch is not operating
correctly:
(A) Turn off the air supply.
(B) Disconnect air line from the throat plate at
the vacuum valve.
(C) Clean any thread or trash from inside the
vacuum generator.
(D) Check all fittings and air lines for tightness
and air leaks.
(E) Check Throat Plate for holes in the tube or
burrs on the chaining finger.
AAP26SE
(770)963-7369 FAX (770)963-7641
ATLANTA ATTACHMENT COMPANY
401 Industrial Park Dr.-Lawrenceville, GA 30045
Panel De Control
1975E-400A
Tiene que haber un surtidor independiente de
presión de aire desde una linea principal al
panel de Control (no "T" o empalmes). Esta
línea debe poder mantener 4 Pies Cúbicos por
Minuto (CFM) de presión de aire a 80 PSI. Si el
Remate Automático no está operando
correctamente:
(A) Apague la presión de aire.
(B) Desconecte la manguera de presión de aire
de la plancha de la aguja a la válvula de
succión.
(C) Limpie cualquier hilo o basura de dentro
del generador de vacío.
(D) Verifique que todos los accesorios y las
mangueras esten bien apretados y chequee
por escapes de aire.
(E) Chequee por orificios en el tubo de la
Plancha de la Aguja y por esquirlas en el
dedo de encadenado.
AAP26SE
1-5