4. FUNCTIONAL DESCRIPTION

4.1. ALTERNATING CURRENT MEASUREMENT

(A range)
Set the switch to A~.
Open the clamp by pressing the trigger.
Place the clamp around the conductor to be measured and
release the trigger; check that the clamp is properly closed. Read the
measurement on the display unit.
Note: As a safety measure, disconnect the measuring cords from the
clamp before performing this operation.
The clamp must be placed around a single conductor of a circuit, since
otherwise the measurement may be thrown off. The measurement is
optimal with the conductor centred in the middle of the jaws

4.2. LEAKAGE CURRENT MEASUREMENT

(mA range)
Note: As a safety measure, disconnect the measuring cords from the
clamp before performing this operation.
The measurement is optimal with the conductor centred in the middle
of the jaws.
Set the switch to mA~.
Open the clamp by pressing the trigger.
Load
600V CAT
III
100A
Press 2 Sec
HOLD
50 / 60Hz