Operating instructions
B-55600-13-4-6
ekey finger scanner
5.2
Connect the mains voltage and perform the test within the next
10 minutes. Once the 10 minutes have elapsed, this test can only be carried
out following a power-on reset of the fingerprint scanner.
Fingerprint scanner
is paired with
SECUREconnect 200.
No fingerprint stored.
NOTE
EN
36
Test mode
Put a finger on the
sensor for 3 - 5 s.
A test can only be performed if a master finger has
not yet been stored or if a mobile device has not yet
been paired.
You can place your finger on the sensor for a
maximum of 5 s. If you leave your finger on the
sensor for longer, the relay will not switch.
If you take the
finger off, the relay
switches.
10.2018 | 20525E | Designed in Germany