PROBLEM
PROBLEM
1. No power, switches do not light up
2. Switches light up, but no flame effect
3. Down lights do not light up
4. Logs Glow, flame effect does not work
5. Flame effect operates, but heater does not
blow warm air
6. If unit heater does not function, but Power and
Heater switches are in the "ON" position and
thermostat is set on "HI"
MANTEL LOCATION
When choosing a location for your new fireplace,
ensure that the general instructions are followed.
Also, for best effect, install the fireplace out of
direct sunlight.
Cold climate installation
recommendation: When installing this
unit against a non-insulated exterior
wall or chase, it is mandatory that the
outer walls be insulated to conform to
applicable insulation codes.
ELECTRICAL SPECIFICATIONS
Voltage:
amps:
watts:
CLE A RAN C E TO COM BUSTI BLES
Keep electrical cords, drapery, furniture and other
combustibles at least 3 feet(0.9M) from the front of
the heater and away from the sides.
TROUBLE SHOOTING GUIDE
TROUBLE SHOOTING GUIDE
120VaC, 60 Hz
12.5 amps
1500 watts
SOLUTION
1a. Check that unit is plugged into a standard
120V outlet
2a. Open front doors, slide curtains to the sides then
remove ember bed and check for any broken or
loose light bulbs
3a. Open front doors, slide curtains to the sides and
check that the light bulb inside the top of the unit is
not broken or loose.
4a. Open back of unit. Check to see if "spinner" is
correctly mounted at to the rear of unit
4b. Check to see if spinning motor is functioning.
If not, call customer service
5a. Check that heater switch is in "on" position.
Switch should light up.
5b. Make certain that thermostat is set toward the
"HI" position
6a. Turn all switches to the "OFF" position and unplug
the unit from the wall outlet for 5 minutes.
After 5 minutes plug the unit back into wall outlet,
and operate as normal.
E LECTRICAL CONNECTION
A 15 AMP, 120 Volt, 60 Hz circuit with a properly
grounded outlet is required. Preferably, the fireplace
will be on a dedicated circuit as other appliances
on the same circuit may cause the circuit breaker
to trip or the fuse to blow when the heater is in
operation. The unit comes standard with 6' (1828
mm) three wire cord, exiting from the rear of the
fireplace. Plan the installation to avoid the use of an
extension cord. If an extension cord must be used,
it must be a minimum 14 AWG, three wire with
grounding type plug connector and rated not less
than 1875 Watts. The cord shall not be more than
20 feet in length.
CLEANING TRIM
Clean the metal trim using a soft cloth, slightly
dampened with a citrus oil based product and buff
with a clean soft cloth. DO NOT use brass polish or
household cleaners as these products will damage the
metal trim. Citrus oil based products can be obtained
at supermarkets or hardware stores.
E-4