3. Installation Preparation. (cont.)
This fan can be mounted as a flushmount
on a regular (no-slope) ceiling only. Downrod
installations are not available for this fan.
Installation requires these tools:
Phillips screwdriver, flat-head screwdriver,
adjustable pliers or wrench, stepladder, wire
cutters, and rated electrical tape.
4. Hanging Bracket Installation.
Turn off circuit breakers to current fixture from
breaker panel and be sure operating light switch
is turned to the OFF position. [Refer to diagram 1.]
WARNING: Failure to disconnect power supply prior
to installation may result in serious injury.
Remove existing fixture.
WARNING: When using an existing outlet box, be
sure the outlet box is securely attached to the
building structure and can support the full weight of
the fan. Ensure outlet box is clearly marked "Suitable
for Fan Support." If not, it must be replaced with an
approved outlet box. Failure to do so can result in
serious injury.
CAUTION: Be sure outlet box is grounded properly
and that a ground wire (GREEN or bare) is present.
Remove 4 motor mounting nuts and flat washers
from hanging bracket--save for later use. [Refer to
diagram 2.]
Install hanging bracket to outlet box using
original screws, spring washers and flat washers
provided with new or original outlet box.* Install
rubber cushions between outlet box and hanging
bracket (if not already pre-attached to hanging
bracket) to reduce vibration of metal to metal
surfaces. Pull electrical wiring from outlet box
through center hole in the hanging bracket. [Refer
to diagram 3.]
*Note: It is very important that you use the proper
hardware when installing the hanging bracket as
this will support the fan.
flushmount
installation
CANNOT be
installed on
angled or
vaulted ceilings
diagram 1
diagram 2
rubber cushions
hanging
bracket
spring washers
outlet box screws
diagram 3
page 3
downrod
installation
hanging bracket
motor
mounting
nuts
flat
washers
flat
washers