ENGLISH
ELECTRICAL INSTALLATION + ADDRESSING
Important: The electrical installation should be carried out by qualified personal only,
according to the regulations for electrical and mechanical safety in your country.
Important remark:
Since the projectors have no display and/or menu buttons, you should configure them first using a separate
unit called "Firmware Updater" (order code: 4319) and a PC-program called "DMX Tools" (to be
downloaded from our website, free of charge). See setup instruction below how to use the PC-software.
Master / Slave installation:
You can install several projectors in a chain without any DMX controller attached: the first projector in the
chain will automatically act as master, the other projectors become the slaves.
Remark: the drawing shows an installation for outdoor use. For an indoor installation you don't have to
use the special "LDP-JUNCTION IP68". You just have to connect the mains cables to 230V ac while the
DMX-in/outputs can be equipped with XLR-connectors if desired. (see below for the exact pinning)
For exact installation instructions using the "LDP-JUNCTION IP68" box: please refer to its user manual!
Electrical installation for two or more units in DMX-mode:
You can install several projectors in a chain with any DMX-controller attached: all projectors in the chain will
be controlled by DMX. (don't forget to setup the projectors first! See setup instructions below)
Remark: the drawing shows an installation for outdoor use. For an indoor installation you don't have to
use the special "LDP-JUNCTION IP68". You just have to connect the mains cables to 230V ac while the
DMX-in/outputs can be equipped with XLR-connectors if desired. (see below for the exact pinning)
For exact installation instructions using the "LDP-JUNCTION IP68" box: please refer to its user manual!
BRITEQ
®
MASTER
SLAVE1
4/44
USER MANUAL
SLAVE2 ...
LDP-GARDENSPOT 4TC