QUICK REFERENCE OF PARAMETERS, ALARMS AND FAULTS
Param.
Description
P956
SoftPLC Parameter 47
P957
SoftPLC Parameter 48
P958
SoftPLC Parameter 49
P959
SoftPLC Parameter 50
SoftPLC Parameter Configuration for PID Controller Application (P903 = 1)
Param.
Description
P910
PID Controller Application Version
P911
Control Setpoint
P912
Control Setpoint 1
P913
Control Setpoint 2
P914
Control Setpoint 3
P915
Control Setpoint 4
P916
Control Process Variable
P917
PID Controller Output
P918
PID Controller Setpoint in Manual
Mode
P919
PID Controller Logical Status
P920
Selection of the Control Setpoint
Source
P921
Selection of the Control Process
Variable Source
P922
Minimum Sensor Level of the
Control Process Variable
P923
Maximum Sensor Level of the
Control Process Variable
P924
Value for Low Level Alarm for the
Control Process Variable
P925
Time for Low Level Fault for the
Control Process Variable
P926
Value for High Level Alarm for the
Control Process Variable
P927
Time for High Level Fault for the
Control Process Variable
P928
Selection of the PID Controller
Control Action
P929
PID Controller Operation Mode
P930
Automatic Adjustment of the PID
Controller Setpoint
P931
Proportional Gain
P932
Integral Gain
22 | CFW300
Adjustable Range
-9999 to 9999
-9999 to 9999
-9999 to 9999
-9999 to 9999
Adjustable Range
0.00 to 90.00
-99.99 to 99.99
-99.99 to 99.99
-99.99 to 99.99
-99.99 to 99.99
-99.99 to 99.99
-99.99 to 99.99
0.0 to 100.0 %
0.0 to 400.0Hz
0 to FFFF (hexa)
Bit 0 = Sleep Mode Active (A750)
Bit 1 = PID in Manual (0) / Automatic (1)
Bit 2 = PV Low Level (A760)
Bit 3 = PV Low Level (F761)
Bit 4 = PV High Level (A762)
Bit 5 = PV High Level (F763)
Bit 6 to 15 = Reserved
0
=
Control
Setpoint
via
Communication Networks (P911)
1 = Control Setpoint via Analog Input AI1
2 = Control Setpoint via Analog Input AI2
3 = Control Setpoint via Electronic
Potentiometer (EP)
4 = Two Setpoints via Digital Input DI3
(P912 and P913)
5 = Three Setpoints via Digital Inputs DI3
and DI4 (P912, P913 and P914)
6 = Four Setpoints via Digital Inputs DI3
and DI4 (P912, P913, P914 and P915)
1 = Control Process Variable via Analog
Input AI1
2 = Control Process Variable via Analog
Input AI2
3 = Control Process Variable via Difference
between Analog Input AI1 and AI2
-99.99 to 99.99
-99.99 to 99.99
-99.99 to 99.99
0.0 to 999.9s
-99.99 to 99.99
0.0 to 999.9s
0 = Disable PID Controller
1 = Enable PID Controller in Direct Mode
2 = Enable PID Controller in Reverse Mode
0 = Manual
1 = Automatic
2 = Select Control to Manual (0) or
Automatic (1) via digital input DI2
0 = P911 inactive and P918 inactive
1 = P911 active and P918 inactive
2 = P911 inactive and P918 active
3 = P911 active and P918 active
0.00 to 99.99
0.00 to 99.99
Factory Setting
0
0
0
0
Factory Setting
2.00
2.00
2.30
1.80
1.60
0.0Hz
HMI
or
0
1
0.00
4.00
1.00
0.0s
3.50
0.0s
0
2
0
1.00
5.00
Prop.
Prop.
ro
ro
ro
ro
cfg
cfg
cfg