Condenser Cleaning; Pressure Switch Refit; Controls And Signals - Solera ECO Soft Manual De Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

If the filter is not cleaned properly, the compressor might go off because of the pressure switch whose activation is
signaled by a red light close to the general switch shown in pic.15.
- Remove the filter from the rear of the machine (see pic.16);
- Clean the filter with a brush or, if possible, with compressed air.
We recommend to clean the filtre at least once a week.
On the right side panel there is a red light (see pic.15). If it switches on, it means that the pressure switch intervened as
the machine reached a high internal temperature.
A too high temperature can be caused by:
4. Dirty filter; remove and clean the filter (see pic.16);
5. The machine is located close to an heating source and its internal temperature increases;
6. The air circulation is obstructed.
Resolve the problem and reset the pressure switch placed on the right rear side of the machine basis close to the general
switch as illustrated in pic.17. If the red light switches off the reset operation was successful.
SoftPremiumCream
- selection of the functioning mode, in a cyclic sequence:
o SOFT MODE - soft mode;
o NIGHT MODE - night mode;
o MOTOR ON - Cold-Switched off;
- if the values of a parameter are changed, it scrolls horizontally between the parametrs in a cyclic sequence;
Do not wash the membrane of the electronic control with abrasive substances or cloths.
Condenser cleaning procedure
Pressure switch refit procedure

Controls and signals

- within the menu, it means to go forward;
- within the menu, it means to go backward ;
- enter the menu;
- exit the menu.
- augers switch on;
- if the values of a parameter are changed, it let you
confirm the selected value (enter) and returns to the
upper menu;
- 25 -

Publicidad

Tabla de contenido
loading

Productos relacionados para Solera ECO Soft

Tabla de contenido