Eaton E5148C24 Serie Instrucciones De Operación página 4

Contador electrónico preconfigurado
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6.2.2 Programming routine Timer
Operating mode Add:
Adding mode
Permanent signal at count value
preset 1 and at count value
preset 2
Timed signal at count value = preset
1 and at count value = preset 2
Reset to zero
Operating mode Sub:
Subtracting mode
Permanent signal at count value
preset 1 and at count value
Timed signal at count value = preset
1 and at count value = zero
Reset to preset 2
Operating mode AddAr:
Adding mode
Permanent signal at count value
preset 1or timed signal at count
value = preset 1 and at count value
= preset 2
Automatic reset to zero
Operating mode SubAr:
Subtracting mode
Permanent signal at count value
preset 1 or timed signal at count
value = preset 1 and at count value
= zero
Automatic reset to preset 2
Operating mode AddbAt:
Adding mode
Timed signal at count value = preset
2 and automatic reset to zero.
A second adding preset counter
(batch counter), programmed preset
value = 1, counts the number of
automatic resets of preset 2.
Permanent signal at count value
preset 1 or timed signal at count
value = preset 1
The reset key sets both counters to
zero, the reset input only sets the
timer to zero.
Operating mode SubbAt:
Subtracting mode
Timed signal at count value = zero
and automatic reset to preset 2.
Batch counter same as in mode
AddbAt.
The reset key sets the timer to
preset 2 and the batch counter to
zero, the reset input only sets the
timer to preset 2.
Polarity of the inputs:
pospol: positive polarity (PNP)
sourcing from +24V
negpol: negative polarity (NPN)
sinking to 0V
4
zero
Unit of time:
Timing in s, 0.1 s, 0.01 s or
0.001 s*
Timing in min, 0.1 min, 0.01 min
or 0.001 min*
Timing in h, 0.1 h, 0.01 h or
0.001 h*
* depending on position of the
decimal point
Timing in h:min:s
Decimal point (resolution):
0
= no decimal point
0.0
= one decimal place
0.00 = two decimal places
0.000 = three decimal places
Preset 1 on–off
on = on
oFF = off
Permanent signal of output 1,
activated at count value
in adding mode and at count value
preset 1 in subtracting mode*
Permanent signal of output 1,
will become passive at count value
preset 1 in adding mode and at
count value
preset 1 in
subtracting mode**
Timed signal of output 1, will
become passive at count value =
preset 1**
Timed signal of output 1, activated
at count value = preset 1*
Duration of timed signal of output 1
can be set from 00.01 s to 99.99 s.
* Activation of relay coil or opto-
coupler when reaching the preset
value
** Relay coil becomes dead or
optocoupler will be locked when
reaching the preset value
MN05401005E
preset 1

Publicidad

Tabla de contenido
loading

Tabla de contenido