General Instructions
AUTO TIME-OUT ADJUSTMENT (SWITCHES 1-3)
•
The ChekPoint controller provides six periods to select from for shutting off the
water when the object is left in front of the electronic eye. The time periods to
select from are: 15 seconds, 30 seconds, 45 seconds, 60 seconds, 3 minutes and
20 minutes. The default setting is 15 seconds.
Note: The chart below indicates the switch positions required for each auto time-out mode.
Auto Time Out Selection
PERIOD
SW(1)
15 seconds
OFF
30 seconds
OFF
45 seconds
OFF
60 seconds
OFF
3 minutes
ON
20 minutes
ON
Water Shut Off Delay Selection
PERIOD
SW(5)
1 seconds
OFF
10 seconds
OFF
15 seconds
ON
30 seconds
ON
Auto Flush Mode
SW (4)
ON - (Enable)
OFF - (Disable)
LOW BATTERY DETECTION
•
A red fl ashing light in the electronic eye indicates low batteries.
•
A solid red light in the electronic eye and no water fl ow indicates the batteries
are dead.
•
New batteries will need to be installed.
TRANSFORMER OPTION:
IMPORTANT: DO NOT plug the transformer into a receptacle until all wiring has been
completed. This type of transformer is designed to be plugged into a 120 VAC
wall receptacle. The transformer is supplied with a 12 foot cable. When used in
conjunction with batteries, the transformer will become the primary power source.
Plug the transformer cable into the wire lead coming from the bottom of the EC-3122
faucet body.
Note: For the Hydro Generator (EC-HYDROGEN) power option, refer to the instruction
manual in the EC-HYDROGEN kit ordered separately. For hard wiring and hard wire
ganging (EC-HARDWIRE) and easy-wire (EC-EASYWIRE) ganging power options , refer to
the instruction manual in each respective kit when ordered separately.
WATER SHUT-OFF DELAY
ADJUSTMENT (SWITCHES 5 & 6)
SW(2)
SW(3)
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
SW(6)
OFF
AUTO-FLUSH (SWITCH 4)
ON
OFF
ON
6
•
The ChekPoint controller provides
four periods to select from for
shutting off the water when the
object is removed from in front of the
electronic eye. The time periods to
select from are: 1 second, 10 seconds,
15 seconds, and 30 second. The
default setting is 1 second.
•
The ChekPoint controller off ers the
option to select the Auto Flush mode
in switch 4 position. When enabled,
the controller will fl ush the Chek-
Point faucet every 12 hours for 25-30
seconds when the faucet is not used.
Default setting from the factory is in
the "off " position.