WARNING
!
The fan must be hung with at least 7' of clearance from
floor to blades (Figure 12).
WARNING
!
The outlet box and joist must be securely mounted and
capable of supporting at least 50 lbs. Use only a U.L.
outlet box listed as "Acceptable for Fan Support of
22.7 kg. (50 lbs.) or less".
WARNING
!
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked "Acceptable for
Fan Support of 22.7 kg. (50 lbs.) or less", and use screws
supplied with outlet box. Most outlet boxes commonly
used for support of light fixtures are not acceptable for
fan support and may need to be replaced. Consult a
qualified electrician if in doubt.
4.1
Securely attach the hanger bracket to the outlet box using
the two screws supplied with the outlet box. (Figure 13).
WARNING
!
Hanger bracket must seat firmly against outlet box. If the
outlet box is recessed, remove wall board until bracket
contacts box. If bracket and/or outlet box are not securely
attached, the fan could wobble or fall.
4. How to Hang Your Ceiling Fan
AT
LEAST
7'
Figure 12
TWO SCREWS
SUPPLIED WITH
OUTLET BOX
Figure 13
Please contact 1-800-654-3545 for further assistance
9
CEILING
FLOOR
OUTLET BOX
HANGER BRACKET
ANTI-ROTATION TAB
emersonfans.com
ETL Model No.: CF320