B
LB757 Ecojet 5/5 R
Nozzle
GPH
0,50
0,60
0,65
0,75
0,85
1,00
0,50
0,50
0,60
0,65
0,75
0,85
1,00
1,10
Esempio :
Thermal power
= 30 kW
Boiler efficency
= 90%
Pression foyer
= 0 mm CE
SUNTEC AS 47 K
3
6
3
1
2
VERIFY:
- That piping system is perfectly sealed;
- That the use of hoses is avoided whenever is possible (use copper pipes preferably);
- That depression is not greater than 0,45 bar, to avoid pump's cavitation;
- That check valve is suitably designed for the duty;
The pump pressure is set at a value of 12 bar during the testing of burners. Before starting the burner, bleed
the air in the pump through the gauge port. Fill the piping with light-oil to facilitate the pump priming.
Start the burner and check the pump feeding pressure. In case the pump priming does not take place during
the first prepurging, with a consequent, subsequent lock-out of the burner, rearm the burner's lock-out to
restart, by pushing the button on the control box. If, after a successful pump priming, the burner locks-out
after the prepurging, due to a fuel pressure drop in the pump, rearm the burner's lock-out to restart the bur-
ner. Do never allow the pump working without oil for more than three minutes. Note: before starting the
burner, check that the return pipe is open. An eventual obstruction could damage the pump sealing device.
ADJUSTMENT DATA
Pump pressure
angle
bar
60°
12
60°
12
60°
12
60°
12
60°
12
60°
12
60°
9
60°
13
60°
12
60°
12
60°
12
60°
12
60°
12
60°
12
Needed burner power
30 kW
= 33,33 kW
90 %
PRIMING AND ADJUSTMENT OF OIL PUMP
SUNTEC AL 35 A
4
4
5
6
3
1
Burner output
Firing head setting
kg/h
index
1,9
0,5
2,4
0,6
2,7
0,7
3,18
0,8
3,5
1,4
4,3
2,5
1,55
1.82
1,92
0,5
2,4
0,6
2,8
0,9
3,1
1,5
3,8
1,6
4,3
2,5
1 - INLET
2 - RETURN
3 - BLEED AND PRESSURE GAUGE PORT
4 - VACUUM GAUGE PORT
3
5 - PRESSURE ADJUSTMENT
6 - TO NOZZLE
5
2
pag.10
Air regulation
index
1,4
1,7
2
2,3
3,1
4,5
0
1,1
0
1,4
1,6
1,8
2,5
3,0
3,2
4,5