contamination should be removed with a damp rag and a simple solution of soapy 
water.  Any damage to the cable may indicate an unsafe condition, and the SRL 
should be removed from service. 
 Inspect the exit bushing for excessive wear, sharp edges or burring. If these 
conditions exist and are beginning to cause damage to the cable, remove the SRL 
from service. 
 Inspect the carabiner gates at the anchorage and attachment ends of the product 
to ensure proper locking function.  If the gates do not close and lock 
automatically, then the SRL should be removed from service. 
 Check the SRL housing for signs of cracking or denting.  Also check for loose 
screws and any bent, cracked or damaged parts.  If the SRL exhibits any structural 
damage, then remove it from service immediately. 
 Ensure that all metal components are free of corrosion, and that there is no 
evidence of cracking, denting or distortion. 
 Ensure that all labels and warnings remain attached and that they are legible. 
 If the SRL fails to pass inspection on any of these points, or if there is any doubt as 
to whether it is in proper working order, immediately remove it from service. 
8.3:  Mandatory Semi‐Annual Inspection 
     ANSI Z359.1‐2007 requires that all fall protection equipment be inspected by a 
competent person other than the user at least once each year.  FallTech strongly 
encourages that all fall protection equipment be inspected by a competent person other 
than the user at least once every six months. 
      This inspection should be noted in the inspection log below, along with any 
deficiencies.  This inspection should also be used as an opportunity to counsel any 
authorized persons with respect to any deficiencies that they may have failed to note in 
their daily inspections. 
Model #:_______________ 
Serial #:_______________ 
Mfg. Date:_____________ 
Inspection 
Inspector
Date 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Section 9:  Maintenance and Storage 
The service life of your FallTech Contractor Series Cable SRL will depend on two factors:  
The environmental conditions of your working environment along with proper care 
(specifically, maintenance and storage). 
     Keeping the SRL clean and free of contaminants will greatly increase the service life 
and will ensure that the SRL will be in proper working order in the event that you need it 
to arrest a fall.  The following steps should be taken periodically: 
Inspection Log 
FallTech Contractor Series Cable SRL 
Comments
15 
Pass/Fail
Corrective
Action to be 
Taken
Approved 
By 