Section 10:  Specifications; Mandatory Disclosures; Performancespecifications; Labels And Markings - Falltech Contractor SRL Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1. Always wear gloves when handling the cable element of the SRL. 
2. Using a damp rag and a mild soap and water solution, wipe down the SRL housing 
to remove soil and surface contaminants.  Ensure that the labels are legible at all 
times. 
3. Use a damp rag and a mild soap and water solution to clean the cable element of 
the SRL.  Allow it to air dry and then use a rag that is damp with a light machine oil 
to condition the cable. 
4. Use a damp rag to clean the surfaces of any connecting hardware. 
5. If there is an excessive build up of paint, oil, dirt tar or other contaminants that 
cannot be removed, remove the SRL from service and have it replaced. 
6. Store in a cool, dry location away from direct sunlight and where it will not be 
exposed to chemical vapors. 
7. This SRL should be hung on a rack or a peg or stored flat on a shelf, stacked no 
more than three high. 
8. Do not throw the SRL into a pile or a locker or storage box, as this may damage 
the housing. 
      FallTech Contractor SRL's do not require recertification .  Provided your SRL passes 
inspection, has been maintained and is in serviceable condition, there is no need to send 
it in.  If your SRL is in need of repair or you are concerned about its condition, return it 
to the place of purchase to arrange and inspection and/or repair through an authorized 
service center.  For further details, contact FallTech. 
Section 10:  Specifications 
     This section contains important information regarding the performance and 
construction of this product.  Pease read and be familiar with this and all information 
contained in this instruction manual. 
10.1:  Mandatory Disclosures 
     This instruction manual addresses foreseeable hazards, uses and applications.  If you 
have questions about your application that are not addressed in this document, contact 
FallTech for additional guidance. 
      It is the responsibility of the employer/issuer of this equipment to ensure that it is 
used in a manner consistent with these instructions.  Failure to do so could result in 
series injury or death.   
      For further reading and additional information, see Section 10.4 for a listing of 
relevant standards with which you should be familiar. 
10.2:  PerformanceSpecifications 
727620 – 20' Contractor SRL 
Max. Capacity:
Max. Allowable Free‐Fall:
Max. Arrest Force:
Deceleration Distance:
Ultimate Strength:
Weight:
 
10.3:  Labels and Markings 
     The label shown below must be present on the product and must be legible.  If it is 
not, remove the product from service. 
310 lbs.
2 feet
750 lbs.
36 inches
3,000 lbs.
10 lbs.
16 
727630 – 30' Contractor SRL 
Max. Capacity:
Max. Allowable Free‐Fall:
Max. Arrest Force:
Deceleration Distance:
Ultimate Strength:
Weight:
727630 – 30' Contractor SRL 
Max. Capacity:
Max. Allowable Free‐Fall:
Max. Arrest Force:
Deceleration Distance:
Ultimate Strength:
Weight:
310 lbs.
2 feet
750 lbs.
36 inches
3,000 lbs.
11 lbs.
310 lbs.
2 feet
750 lbs.
36 inches
3,000 lbs.
11 lbs.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

727620 srl727630 srl727650 srl

Tabla de contenido