LIFT CORPORATION Sht. 7 of 42 DSG#
12. Connect #6 face seal connector
and elbow (Kit items) to pump
port A, as shown in FIG. 7-1.
Connect #6 face seal connector
(Kit item)to open side of needle
valve (FIG. 7-1).
13. Next, connect needle valve (Kit item)
to elbow on pump port 'A' (FIG. 7-1).
Do not tighten connectors until later in
this procedure.
CAUTION
For correct hand pump operation,
arrow on fl ow regulator valve must
point toward connection on the
branch tee.
14. Connect SAE #6 fi tting (Kit item), 3 GPM fl ow
valve (Kit item), and branch tee (Kit item) to the
adapter fi tting (FIG. 7-2). Do not tighten con-
nectors until later in this procedure.
© MAXON Lift Corp. 2019
CONNECTOR,
FACE SEAL #6
(P/N 905173)
CONNECTING ELBOW, NEEDLE VALVE
CONNECTING HIGH PRESSURE FLOW
M-13-07
Rev. D Date: 03/22/19
CONNECTOR,
FACE SEAL #6
(P/N 905173)
& CONNECTORS
FIG. 7-1
VALVE & FITTINGS
FIG. 7-2