9. OPERATION
Always turn your blower on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few
minutes to clear the air after you turn off the range.
A
HC0016
A) Blower Delay switch
B) ON blower/Speed control switch
C) OFF blower/Filter maintenance switch
A. B
:
LOWER DELAY SWITCH
When a speed is selected, press the delay switch to activate the delay function. The corresponding speed indicator LED
will start flashing to indicate this function is activated. The fan will continue to operate for 5 minutes and will stop
automatically. To cancel the delay function, press the blower delay switch once again; the blower will then work in
normal mode.
NOTE: The blower speed can be increased—or decreased—during delay mode without starting another 5-minute cycle.
B. ON
/S
BLOWER
PEED CONTROL SWITCH
Press this switch to turn on the blower at the last selected speed. To change the blower speed, press the switch again
until the desired speed is obtained.
NOTES: 1. Each time you press the speed control switch, the speed changes by increments of 1 (e.g.: speed 1
to speed 2, to speed 3, and then speed 4.) From the fourth speed, the speed goes down to level 1.
2. The last speed used is kept in memory so that when the unit is turned on, it will return to the last setting
except the fourth, the next time the blower will be turned on, it will return to speed 3.
HEAT SENTRY™
This hood is equipped with a Heat Sentry thermostat. This thermostat is a device that will turn on or speed up the blower
if it senses excessive heat above the cooking surface.
1) If blower is OFF—it turns blower ON to speed 3.
2) If blower is ON at a lower speed setting—it turns the blower up to speed 3. If blower is at Boost, HEAT SENTRY™
turns blower down to speed 3.
When HEAT SENTRY™ is activated, the last speed blower LED is flashing.
When the temperature level drops to normal, the blower will return to its original setting.
The HEAT SENTRY™ can start the blower even if the hood is turned OFF. In this case, it is impossible to
turn the blower OFF with blower switch. To prevent the blower from starting, turn off power at the
main electrical panel.
C. OFF
/F
BLOWER
ILTER MAINTENANCE SWITCH
Press this switch to turn off the blower. Pressing this switch also cancels the delay function (if activated).
NOTE: After 25 hours of operation, all blower LEDs will flash during 30 seconds to indicate the filters need to be
cleaned in order to maintain efficient hood operation. The LEDS will continue to flash until the function is reset
by pressing on this switch for 3 seconds.
D. OFF
:
LIGHTING
Press this switch to turn off lighting.
E. H
:
ALOGEN LIGHT SWITCH
Press this switch to turn on the halogen lamps. The lighting intensity changes by increments of 1 (e.g.: Press once for low
intensity, once again to get more, up to three times.) From the higher intensity, press once to go back to the lower intensity.
NOTE: The last lighting intensity used is kept in memory. The next time the halogen lamps will be turned on, they will
light with the last intensity used.
R
ESET CONTROL PROCEDURE
If ever the control locks up, turn off power at the main electrical panel for 5 seconds. Then, turn on power at the main
electrical panel. The control will be reset.
B
:
!
:
:
C
D) OFF lighting
E) Halogen light switch
WARNING
- 12 -
D
E