Existing Construction – accessible only from below
D11
EXISTING FAN
Remove an existing fan and check to make sure the
opening is large enough to accommodate the new
motor housing (8"x 8.5").
D13
pull wires through strain relief
D15
Install the housing flush with the sheetrock and secure
by tightening the pre-loaded screws into the joist.
.
E
43043-01 01/24/2008
D12
Move the housing into position above the ceiling.
D14
Attach existing ducting to duct connector. Tape joints.
If ducting does not fit securely,
an adapter may need to be purchased.