MAINTENANCE OF MOTORS
WARNING: Make sure all power to the appliance is turned OFF
before proceeding.
Always disconnect the appliance from the main power supply and allow it to
cool before any servicing operation. The motor used on the flame blower is pre-
lubricated for extended bearing life and requires no further lubrication. However,
periodic cleaning/vacuuming of the appliance around the air intake and exhaust,
as well as the blower is recommended. For heavy or continuous use, periodic
cleaning must be done more frequently. If the heater blows alternating cold and
warm air, check the blower for free movement and for debris restricting air flow.
If the blower does not move freely, the unit must be turned off and the blower
replaced immediately in order to prevent further damage to the unit.
Troubleshooting
PROBLEM
Blower is not
spinning.
Blower is mak-
ing a loud noise.
This product includes a warranty against any defect in materials and
workmanship for a period of one (1) year from the date of retail sale. Contact our
Consumer Warranty Dept. for more information (800) 776-9425.
POSSIBLE CAUSE
1. There is no power to
the blower.
2. Blower is set to
AUTO "
".
3. Blower motor is bad.
1. Blower housing or
blades are dirty.
2. Blower rotation is
blocked.
3. Defective blower.
CORRECTIVE ACTION
1. Verify blower is plugged in and
set to MAN "
AUTO "
2. Allow 5-10 minutes for blower
to engage.
3. Replace blower.
1. Clean blower and blower
housing.
2. Verify wiring is not in blower
path.
3. Replace blower.
9
" or
".
Printed in China