trapped air. Once the gun has been primed, fully tighten the grease gun head onto the
barrel.
8. Push the plunger rod into the barrel for easier maneuverability during use.
9. You should now connect the grease gun extension and coupler onto the grease gun outlet.
The connection between the extension and grease gun must be tight and it is advisable to
use a thread sealant to ensure a leak-proof joint.
CAUTION
Do not apply excessive torque or over-tighten the grease gun extension as this will apply
undue stress to the die cast outlet and may cause it to fracture.
10. Press and release the trigger several times until grease flows out from the coupler. The
grease pressure can be adjusted by regulating the inlet air pressure. Grease pressure is 40
times greater than the air inlet pressure.
LOADING GREASE GUN USING BULK GREASE
NOTE: Always remove any cartridges from the grease gun prior to bulk filling.
1. Make sure the gun is disconnected from the air supply. Loosen but do not remove, the
grease gun head from the grease gun barrel by turning the grease gun head in a counter
clockwise direction 1 ½ turns. Pull back the plunger rod handle all the way to the end & lock
the handle.
2. Now rotate the grease gun head in the counter- clockwise direction to unscrew the grease
gun head from the barrel completely. Release plunger handle and allow the handle to move
to its most forward position.
3. Insert the open end of the barrel about 2" into the grease.
4. Slowly pull the plunger rod handle while pushing the barrel deeper into the grease until the
plunger rod is all the way extended.
5. The grease gun barrel should now be filled with grease. The barrel's outside surface will
have a lot of grease sticking to it, wipe off all excess grease before use.
6. Screw the head of the gun onto the barrel, but do not fully tighten the barrel. For now leave
at least 2-3 turns before the barrel is fully tightened against the gasket in the head.
7. Unlock the plunger rod handle from the end cap.
8. Move the plunger rod forward and backward to force out any trapped air pockets from the
grease. Air will escape from the connection between the grease gun head and the barrel,
which is not fully tightened.
9. Reconnect the air supply and "prime" the system by pressing and releasing the trigger until
the grease starts coming out of the discharge nozzle. Initial grease discharge may have
trapped air. Once the gun has been primed, fully tighten the grease gun head onto the
barrel.
10. Push the plunger rod into the barrel for easier during use.
11. You should now connect the grease gun extension and coupler onto the grease gun outlet.
The connection between the extension and grease gun must be tight and it is advisable to
use a thread sealant to ensure a leak-proof joint.
CAUTION
Do not apply excessive torque or over-tighten the grease gun extension as this will apply
undue stress to the die cast outlet and may cause it to fracture.