The "Bypass" mode is entered by pressing keys + and – simultaneously.
ON:
ESA BASIC keeps the control unit connected to it always on. In this way, parameters and logics of the control unit
can be preset, thus avoiding that the control unit enters the SLEEP mode.
N.B.: when the BYPASS mode is ON, the wording "ON" is displayed.
OFF:
ESA BASIC works regularly.
The programming of the various functions of the control unit is carried out by using the LCD display on the control unit and
presetting the desired values in the programming menus described hereunder.
USE OF THE PROGRAMMIN PUSH BUTTONS
Press OK to access the Main Menu (PAR>>LOG>>RADIO>>...) that can be selected by pressing keys + and -.
Select the Main Menu by pressing <OK> to access the desired Function Menu.
See section "Programming Example".
NOTE:
If keys <+> and <-> are pressed simultaneously from a Function Menu, this allows to return to the upper menu without
making any changes.
To speed up the increase/decrease of values, keep key <+> or key <-> pressed.
After waiting 30 seconds, the control unit exits the programming mode and switches the display off.
The single functions available in the control unit are described in the following table.
MENU
Self-switching off time: when the preset time has elapsed, if the system is
still in standby mode (powered control unit with motor stopped), ESA cuts off
power to the control unit.
If one of the N.C. inputs is kept open (e.g. photocell obscured), the self-
toff
switching off time will not be calculated until the input recovers its regular
operating mode.
N.B.: preset a TOFF higher than the TCA time preset in the control unit.
Start Delay channel 1: delay between the activation of input 1 and its replication
OUT 1 when the control unit is in SLEEP mode (this delay is the time required
STD1
for the control unit to switch on and being able to receive a control signal sent
by ESA).
Start Delay channel 2:
STd2
-------
----
Start Delay channel 6:
STd6
The switch time of the channel 1 relay is preset.
tch1
The switch time of the channel 2 relay is preset.
TCH2
-------
----
The switch time of the channel 6 relay is preset.
TCH6
BYPASS MODE
HOW TO PROGRAMME
PARAMETERS, LOGICS AND SPECIAL FUNCTIONS
FUNCTION
MIN-MAX
MEMO
(Default)
10-3600 sec
(60)
0.1-15.0 sec
(2,0)
0.1-90.0 sec
(1,0)
11