Btl5-S1; Proper Application - Balluff Micropulse BTL5-S1 Serie Manual De Instrucciones

Transductor de desplazamiento
Ocultar thumbs Ver también para Micropulse BTL5-S1 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL5-S1_ _-M_ _ _ _A/B/Z-S32/S147/KA_ _
Micropulse Linear Transducer - Rod Style
Contents
1
Safety Advisory .................... 2
1.1 Proper application ................. 2
1.2 Qualified personnel ............... 2
1.3 Use and inspection ............... 2
1.4 Scope ..................................... 2
2
Characteristics ..................... 3
2.1 Characteristics ...................... 3
2.2 Function ................................. 3
2.3 SSI interface .......................... 3
3
Installation ............................ 4
3.1 Mounting ................................ 4
4
Wiring .................................... 6
4.1 Connector S32 ....................... 6
4.2 Connector S147 ..................... 6
4.3 Cable KA_ _ .......................... 6
5
Startup .................................. 7
5.1 Check connections ................ 7
5.3 Check output values ............. 7
5.4 Check functionality ................ 7
5.5 Fault conditions ..................... 7
6
part label) .............................. 7
6.1 Included in shipment ............. 7
6.2 Available lengths ................... 7
7
Accessories .......................... 8
7.1 Magnets ................................. 8
7.2 Connectors ............................ 8
7.3 Compatible devices .............. 8
7.4 Mounting nut .......................... 8
8
Technical Data ...................... 9
ambient conditions ................ 9
8.3 Control signals ....................... 9
The following patents have been
granted in connection with this
product:
US Patent 5 923 164
Apparatus and Method for Auto-
matically Tuning the Gain of an
Amplifier
2
english
1
Safety Advisory
Read this manual before installing
and operating the Micropulse Trans-
ducer.
1.1

Proper application

The BTL5 Micropulse transducer is
intended to be installed in a ma-
chine or system. Together with a
controller (PLC) or a processor it
comprises a position measuring
system and may only be used for
this purpose.
Unauthorized modifications and
non-permitted usage will result in
the loss of warranty and liability
claims.
1.2
Qualified personnel
This guide is intended for special-
ized personnel who will perform the
installation and setup of the system.
1.3
Use and inspection
The relevant safety regulations must
be followed when using the trans-
ducer system. In particular, steps
must be taken to ensure that should
the transducer system become de-
fective no hazards to persons or
property can result. This includes
the installation of additional safety
limit switches, emergency shutoff
switches and maintaining the per-
missible ambient conditions.
1.4
Scope
This guide applies to the model
BTL5-S1...A/B/Z... Micropulse
transducer.
An overview of the various models
can be found in chapter 6 Versions
(indicated on product label) on
page 7.
Note: For special versions, which
are indicated by an -SA_ _ _ des-
ignation in the part number, other
technical data may apply (affect-
ing calibration, wiring, dimensions
etc.).

Publicidad

Tabla de contenido
loading

Tabla de contenido