ECOPOSTURAL C6203 Instrucciones De Uso página 9

Camilla eléctrica
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

English
Then, he can lie down. Weight must necessarily be distributed evenly and not concentrated on either side
of the table.
When getting down the table different procedures apply depending on the position of the patient.
Therefore, if he is lying down (prone position) he has to slide gently towards the middle of the table, lean
on his side and go up by standing on his arms. He will then be able to put his legs out by the table's side
and easily stand up.
If the patient is lying upwards he will have to stand on his arms, get back to a seated position and then go
down the table.
* Caution: Never use the head or back rest sections to lean forward as these parts are not aimed at
supporting such a pressure.
c) HEIGHT adjustment
The central height of the table is operated by an electric motor.
The motor supplied in our electric tables is sent disconnected. Before plugging the table in, connect the air
pipes according to the attached instructions.
To operate the supply cable must be plugged into a 220-230 V socket.
SAFELY POSITION PATIENT BEFORE TABLE HEIGHT ADJUSTMENT.
Do not insert hands, feet or garments into the moving parts of the elevating mechanism as
this could result in serious injuries.
For adjusting the height use the foot pedal. Press the foot control switch pedal: left downwards / right
upwards.
d) SECTIONS adjustment
The head-/backrest section is operated by rack (2)
The central section is operated by rack (2)
(2) Rack: Lift the section up to the required position and the rack will position itself automatically. To lower
the section, first raise it up to a certain extend or completely (as appropriate) in order to release the rack.
* The hinges on both sides must be properly fixed and positioned at the same height.
NEVER adjust any of the table sections WHILE THE PATIENT IS LEANING ON.
Safely position your FINGERS AND HANDS AWAY from the upholstery edge to avoid any
accidental jamming.
e) ACCESORIES Adjustment
The table you've bought includes the FACE CRADLE A4430.
It is stored underneath the upholstery and fixed by means of 3 clamps. To remove the face cradle simply
hold the metal frame and pull.
To install the face cradle, insert the bolts through the holes provided at the edge of the table.
You can adjust the cradle tilt by loosening the grips, then place it at the required position and tighten the
grips.
3) MAINTENANCE
For safety reasons, DISCONNECT THE TABLE from the electrical supply before the table
cleaning, repair or servicing.
* Ensure that the toothed pieces fit together
correctly before tightening them again.
9