4 Power Connect
4.1 Structure and function
The Power Connect provides two short circuit proof 24 V and two 0 V output channels with a maximum
output current of 1 A per channel. The electrical connection is established via 4 mm safety sockets.
Assignment
Socket 0
24 V
4.2 Commissioning the Connect
Proceed as follows:
1. Insert the Connect into the base.
2. The Connect is detected automatically by the base.
3. If the iEasyLab software has been started, the Connect will be detected and shown on the display.
4.3 Technical data
Electrical/mechanical specifications
Operating voltage
Output voltage / current per channel
Connection
Size
Weight
Subject to change
38
Socket 1
0 V
The port assignment of the Connect that
has been inserted into the base will be
displayed on the iPad after starting the
iEasyLab software.
Socket 2
24
24 V DC
24 V DC / 1 A
4 mm safety sockets
71 mm x 40 mm x 30 mm
42 g
Socket 3
0 V
© Festo Didactic 8034153