Connection To The Flue Pipe; Hydraulic Connection - de manincor FK600 Instrucciones De Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

At a depression below 0.15 mbar, the fire will burn too slowly
and form carbon residue excessive gases. If instead
depression is any greater, combustion will be too fast and not
transmits much heat to the boiler, the heating plate and the
oven, and will make large operating times impossible.

CONNECTION TO THE FLUE PIPE

The cooker is delivered with the connection corresponding to
the flue exit chosen when ordering:
THERMOCOOKERS
Above
Fix
Rear
Fix
Side
Telescopic
THERMOSTOVES
Above
FiX
EACH COOKER SHOULD HAVE ITS OWN FLUE PIPE; DO NOT
USE THE SAME FLUE PIPE FOR MORE THAN ONE APPLIANCE.
THE COOKER SHOULD BE CONNECTED TO THE FLUE PIPE
AVOIDING AS FAR AS POSSIBLE ANY BENDS, DIVERSIONS AND
DOWNWARD OR HORIZONTAL SECTIONS.
1. Pipe is too long and
on inclined plane
2. Pipe narrower than outlet hole
3. Leaky cleaning panel
NO
1
2
3
Connecting pipes must be perfectly sealed to each other and
to the stove and flue pipe. These precautions must be taken:
• use a seal to avoid infiltration of air into the flue;
Cast Iron
Ø 140 mm
Cast Iron
Ø 140 mm
Steel
Ø 140 mm
Steel
Ø 150 mm
4. Sealed connections
5. Inspection
6. Cleaning
YES
5
4
6
• the pipe must not be narrower at the end;
• the end of the pipe must not protrude into the flue.
NO
2.5 HYDRAULIC CONNECTION TO THE HEATING
SYSTEM
The appliance must be installed by a qualified hydraulic
technician in accordance with regulations on cookers
that use solid fuels.
Thermocookers and thermostoves are endowed with boiler to
use the heating produced by the device through a system
with fluid vector for heating and for the production of hot
water. The appliance must be designed according to UNI
10412-2:2006 law by a qualified thermal technician and
must be installed by experienced people according to exist-
ing laws in particular to UNI 10683:2005 law.
The appliance are endowed with all the necessary predisposi-
tions for a correct installation, every external component (as
pumps, valves, acoustic alarms, pressure switches) must be
obtained by third parts according to the specifies of designer
and installer.
Before the lighting of the thermal cooker it is compulsory to
make the connections to the heating system. The use of the
appliance with empty or not connected to the system boiler
causes the irreversible damaging of the boiler itself.
Anyway, it is necessary to connect the going connector, the
return connector and the discharge connector (necessary to
empty the boiler in case of maintenance), the other connec-
tors according to the kind of system that you make could be
not necessary and so in this case you must cover them.
DeManincor accepts no liability for damage or harm to
objects or persons if the system is not fitted properly or does
not respond to regulations in force.
8
NO
NO
Pipe too
Unsealed
far in
connection
YES
correct
connection

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fk900Fka900Ek90Ekb110