KC3000/3050/3060/3080/4000/4050- KC3005/3055/3065/3085/4005/4055
B
B
A
4)Ifthemainsvoltagecorrespondstotheindicationsonthelabelfixedon
themotor,youcanplugtheunitin.Itisprohibitedtouseextensionsor
looseplugsnottostandards.
Theelectrical systemtheappliance isconnectedtomustbemadein
conformitywiththelawsinforceinthecountryofinstallation.
Itisrecommendedtohaveadifferentialthermomagneticswitch,with
sensitivityequalto30mA,upstreamfromthepowersocket.
Thisis,at50Hz:
Accordingtosub-clause2.2.2ofEN61000-3-11:2000theapparatus
meetsthestandardifconnectedtouser'ssupplywiththefollowing
maximumpermissiblesystemimpedance:
•Zneutral50Hz=0.024
•Zphase50Hz=0.037
INSTALLATION
1)Checkthattheoillevelisalwaysover
2)Connectthehighpressurehoseto the
3)Connectthewatersupplypipe
C
WARNING:
The earth connection is compulsory.
thedipstickmark(A).
outletconnection(B).
(diameternotlowerthan14mm)to
thepumpinletconnection(C).
Makesurethat thesuctionfilterofthe
suctionhoseconnectionisalways
clean.
Thedirtyfiltercausesabadwater
supplyandconsequently abadpump
operationwiththeinevitableriskof
rapidwearingoutandbreakageof
internalmechanisms.
25