Fig. 1: EcoDrift Parts Diagram
1.
Filter basket
2.
Impeller
3.
Pump housing
4.
Rubber gasket
Available spare parts: Please refer to www.aqua-medic.de.
The EcoDrift is for under water operation, only. The max. water depth is 1 m | 40 in. We
recommend to place the pump at least 10 cm | 4 in beneath the surface to prevent the pump from
pulling air. The EcoDrift is designed as a current pump, thus cannot be connected to any piping.
The pump has a ceramic bearing, which has a break-in period of a few days. During that time a
slightly higher noise level may be noticed.
Mounting the EcoDrift pump:
The pump is mounted to the aquarium glass with its magnet holder. Once the location of the pump
is determined and the area is prepared for placement, please follow these instructions:
Carefully disconnect the outside magnet (9) from the pump holder without dislodging the vibration
dampener (7) from the pump holder (6). Now,
aquarium at the requested place of the
attached from the outside in the correct position. Never remove the external magnet without turning
off the pump previously and hold it tight.
To prevent the pump from pulling air, be sure to place it at least 10 cm | 4 in beneath the surface.
To prevent the pump from disturbing the sand bed, avoid mounting it too close, or pointing it to the
bottom of the aquarium. The pump can be adjusted in any direction by simply turning the magnet
(9), be sure to hold the pump preventing it from falling, as well as turning the pump in its holder
(6).
Note: Even though the pump comes with a strong magnet holder that holds the pump securely in
place, we recommend to place the pump away from expensive animals in case it becomes dislodged
from the aquarium glass.
The pump is open at the front. Avoid operating the pump via a timer. Small animals could
enter the pump while it is shut-off, and could cause damage to the pump and animals when starting.
Safety advices
The pump is constructed for indoor aquarium use only. The connection cable and the
power plug must not be replaced. If the power cable is damaged, the pump must be
scrapped.
4. EcoDrift Control 0 – 10 V
To produce irregular flows, the EcoDrift Control is switched between power supply and pump. Protect
it from condensate and respect a
smaller and cannot be used for controlling the larger types. Furthermore, it has not a port
for a light sensor.
8
6.
Pump holder
7.
Vibration dampener with inner magnet
8.
Rubber gasket
9.
External magnet
the pump with the holder has to be placed in the
aquarium glass
maximum of 80% air humidity.
and then the second magnet has to be
The EcoDrift Control
4.1 is