• Filter pads should be replaced annually. Use smartpond
Replacement Filter Pads model #52286 (MFRP) or #52512
(MFRPCA).
• The exterior surface of the filter box may also need occasional
cleaning. Particularly if the openings in the top of the filter box
are obstructed. When cleaning the filter box use warm water
only. Do not use any chemicals that may destroy the beneficial
bacteria.
NOTE: The bio-balls in your filter system and the inside surfaces
of the filter box contain the beneficial bacteria. At least once
a year the entire system should be disassembled and cleaned
thoroughly using warm water. This should not be done during the
warm season as it may take up to 8 weeks to re-establish the
environmental balance. The best time of the year to "breakdown"
your system is in early spring before the water temperatures
begin to rise. This is also the ideal time to replace the filter pads.
• Reassemble all part and place in water before recoonecting to
the power source.
PUMP
Regular cleaning of the pump may be necessary depending upon
the environment which it is operated. Clean the pump when it is
visibly soiled or when a drop in performance is detected. Clean
pump in 4 easy steps!
Step1: Before cleaning, always
disconnect the pump from the
power source and remove the
pump cover.
Step 2: Remove the impeller
cover to expose the impeller
assembly. Remove the impeller
assembly by gently pulling on the
impeller blades. The impeller is
held in place by a magnet.
Step 3: Use a soft cloth or brush
and warm water to clean the
impeller and the inside of the impeller housing.
Step 4: Reassemble all pump parts and place in water before
reconnecting to the power source.
TROUBLESHOOTING
IF THE PUMP FAILS TO OPERATE:
• Check to make sure the power cord is plugged in and the pump is
getting power.
PLEASE CALL CUSTOMER CARE BEFORE RETURNING ITEM TO LOWE'S: 1-888-755-4497
®