INSTALLATION INSTRUCTIONS
BEFORE YOU BEGIN
Read these instructions completely
and carefully.
IMPORTANT-
instructions for local inspector s use.
IMPORTANT-
governing codes and ordianaces.
Note to Installer
instructions with the Consumer.
Note to Consumer
instructions for futrue reference.
-
Skill level
Installatio of this appliance
requires basic mechanical skills.
Completion time
We recommend that two people install
this product.
Proper installation is the responsibility
of the installer.
Product failure due to improper installation
is not covered under the Warranty.
You MUST use all supplied parts and use
proper installation procedures as described
in these instructions when installing this air
conditioner.
NOTE:
These instructions describe installation in a typical
wood framed window with a wood SLIDE-BY sash, or
installationin a metal CASEMENT window.Modification
may be necessary when installing in windows made
differently than those shown in these instructions.
A high widow accessory kit is available for window
heights up to 62 (1575mm).
NOTE:
Save Carton and these Installation Instructions for future
reference. The carton is the best way to store unit during
winter, or when not in use.
When handling unit, be careful to avoid cuts from sharp
metal edges and aluminum fins on front and rear coils.
Meeting Electrical Requirements
WARNING
Electrical Shock and Personal Injury Hazard
Electrical ground is required on this appliance.
DO NOT ground to a gas line.
Save these
Observe all
-
Be sure to leave these
-
Keep these
-
Approximately 1 hour.
If cold water pipe is interrupted by plastic,
non-metallic gaskets, or other insulating
materials, DO NOT use for grounding.
Check with a qualified electrician if you are
in doubt as to whether the appliance is pro-
perly grounded.
DO NOT modify power supply cord plug. If it
does not fit outlet, have a proper outlet
installed by a qualified electrician.
DO NOT have a fuse in the neutral or
grounding circuit. A fuse in the neutral, or
grounding circuit could result in an electrical
shock.
DO NOT use an extension cord with this
appliance.
Failure to follow these instructions could result
in electrical shock, serious inju ry, or death .
Observe all local governing codes
and ordinances.
Do not, under any circumstances,
remove the power supply cord
grounding prong.
NOTE:
If codes permit, and a separate grounding
wire is used; it is recommended that a qualified
electrican determine that the grounding path is
adequate and not interrupted by plastic, non-
metallic gaskets, or other insulating materials.
Receptacle wiring
Receptacle wiring should be a minimum of 14
gauge. Use copper wire only. It is your responsibility
to provide proper and adequate receptacle wiring,
installed by a qualified electrician.
Electrical requirements
A time delay fuse or time delay circuit breaker is
also required. A separate circuit, serving only this
appliance, MUST be provided.
Preparing for Installation
Installation Tips
For wood-frame casement windows:
necessary to construct a frame, using at least 1-inch thick
wood, with a 15-1/2-inch wide opening.
For brick or cement building construction:
be necessary to put a wood stool strip under AC, for
mounting purposes.
Tools Required:
Flat-head screwdriver;Phillips-head screwdriver
Carpenter s level;Tape measure
Fine tooth saw;Electric or hand drill
4
It may be
It may