Disconnect power before working on
pump, motor, pressure switch or wiring
Motor may be hot. Allow to cool 20
!
minutes.
Water pressure may have built up in
!
the pump, pipes and/or tank. Drain
water to relieve pressure.
Motor Switch Settings (Figure 8)
Motors are designed to run on either 115 volt or 230 volt
current. Be sure switch is set properly for the incoming
voltage. SETTING SWITCH FOR INCORRECT VOLTAGE
WILL DAMAGE MOTOR AND VOID WARRANTY! IF YOU
DO NOT KNOW THE SUPPLY VOLTAGE CONTACT LI-
CENSED ELECTRICIAN.
Wiring Pressure Switch
Attach the wires from the power source to the pressure
switch following the directions provided under the cover
of the pressure switch. Remove the pressure switch cover
and follow wiring directions under the cover lid. Be sure the
ground wire is properly connected (Figure 9).
Wiring
Risk of electric shock.
Can shock, burn or kill.
1. To avoid dangerous or fatal electrical shock, turn OFF
power to circuit before working on electrical
connections.
2. Ground motor before connecting to electrical power
supply. Failure to ground motor can cause severe or
fatal electrical shock hazard.
3. Supply voltage must be within +/- 10% of nameplate
voltage. Incorrect voltage can cause fire or damage
motor and voids warranty. If in doubt consult a
licensed electrician.
Wiring Chart Recommended Wire and Fuse Sizes for 115 and 230 volts
MOTOR HP
VOLTS
1/2
115/230
3/4
115/230
1
115/230
MOTOR HP
VOLTS
1/2
115/230
3/4
115/230
1
115/230
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561

ELECTRICAL

SHALLOW WELL
MAX. LOAD
BRANCH FUSE
AMP
RATING AMP
12.2/6.1
20/15
11.1/5.1
15/15
11.4/5.7
15/15
CONVERTIBLE WELL
MAX. LOAD
BRANCH FUSE
AMP
RATING AMP
10.8/5.4
15/15
11.5/5.8
15/15
11.9/6.0
15/15
Figure 8
4. Use wire size specified in Wiring Chart (below). If
possible, connect pump to a separate branch circuit
with no other appliances on it.
5. Do not ground to a gas supply line.
6. Wire motor according to diagram on motor nameplate.
If nameplate diagram differs from diagrams above,
follow nameplate diagram.
7. If this procedure or the wiring diagrams are
confusing, consult a licensed electrician.
8. All wiring, electrical connections and system
grounding must comply with National Electrical Code
(NEC) and with any local codes and ordinances.
Employ a licensed electrician.
DISTANCE IN FEET FROM MOTOR TO SUPPLY
0-100
101-200
AWG WIRE SIZE (mm2)
12/14 (4/2.5) 8/14 (10/2.5) 6/14 (10/2.5)
12/14 (4/2.5) 10/14 (6/2.5) 8/14 (10/2.5)
12/14 (4/2.5) 10/14 (6/2.5) 8/14 (10/2.5)
DISTANCE IN FEET FROM MOTOR TO SUPPLY
0-100
101-200
AWG WIRE SIZE (mm2)
12/14 (4/2.5) 10/14 (6/2.5) 8/14 (10/2.5)
12/14 (4/2.5) 10/14 (6/2.5) 8/14 (10/2.5)
12/14 (4/2.5) 8/14 (10/2.5) 8/14 (10/2.5)
9
(Figure 9) Remove
Motor End Cover
to Access Voltage
Switch (some
models only)
201-300
301-400
401-500
6/12 (16/4)
4/10 (25/6)
6/12 (16/4)
6/12 (16/4)
6/12 (16/4)
6/12 (16/4)
201-300
301-400
401-500
6/12 (16/4)
6/12 (16/4)
6/12 (16/4)
6/12 (16/4)
6/12 (16/4)
6/10 (16/6)