Analog Output Option (0917-0246) - Mettler Toledo PANTHER Guia De Instalacion

Ocultar thumbs Ver también para PANTHER:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
METTLER TOLEDO PANTHER/PANTHER PLUS Terminals Installation Guide
Analog Output Option
(0917-0246)
3-2
(7/03)
The Analog Output Option Kit provides output ranges of 0-10 VDC or 4 - 20 mA plus an
optically isolated open collector status indication output. The Analog Output PCB may
be installed in either the harsh environment PANTHER and PANTHER PLUS terminals or
in the panel-mount PANTHER terminal.
The maximum recommended cable length for the 0-10 VDC output is 50 feet (15.2
meters). The recommended cable is shielded 2-conductor stranded 20-gauge cable
(Belden #8762 or equivalent, available from METTLER TOLEDO using part number
510220190.
4 to 20mA
1
4-20mA
2
GND
3
N.C.
J2
4
0-10 VDC
5
ALRM*
6
+5 VDC
0 to 10 VDC
1
4-20mA
2
GND
J2
3
N.C
4
0-10 VDC
5
ALRM*
6
+5 VDC
Analog Output Terminal Strip
1
2
3
J2
4
5
6
Customer
Device (4-20mA)
+
-
Customer
Device (0-10VDC)
-
+
4-20 mA
GND
N.C.
0-10 V
ALARM
+5V