Stobag MOVENO DWIRE-V Serie Instrucciones Y Advertencias Para La Instalación Y El Uso página 16

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4) Programming
A reverser switch, enabling the simultaneous activation of both elec-
tric motor phases, must be used to program the travel limits.
The special MA 2001 control unit can be used for this purpose. Button
▲ is used to raise the shutter/awning; button ▼ is used to lower it.
Table "A1"
Programming the "0" and "1" positions (fig. 7)
Press and hold down the ▲ control to raise the shutter.
1.
Release the ▲ control when the shutter has reached "Position 0".
2.
Operate the ▲ and ▼ controls as many times as necessary to adjust the position.
Press and hold down the ▲ and ▼ controls simultaneously.
3.
4.
Wait approximately 3 seconds for the shutter to move briefly down and up.
Release the ▲ and ▼ controls.
5.
Press and hold down the ▼ control to lower the shutter.
6.
Release the ▼ control when the shutter has reached "Position 1".
7.
Operate the ▲ and ▼ controls as many times as necessary to adjust the position.
Press and hold down the ▲ and ▼ controls simultaneously.
8.
9.
Wait approximately 3 seconds for the shutter to move briefly up and down.
Release the ▲ and ▼ controls.
10.
If the motor is moved after programming, the memorized positions must be erased:
Table "A2"
Erasing the "0" and "1" positions (fig. 8)
Press and hold down the ▲ and ▼ up and down controls simultaneously.
1.
2.
Wait approximately 3 seconds for the shutter to move briefly up and down.
3.
Release one of the buttons (▼, for example) while still pressing the other one.
4.
Press and release the button (released at step 3) three times within 3 seconds from the time
the shutter moved up and down momentarily.
5.
Release the other button as well.
5) What to do if...
a brief troubleshooting guide!
The motor stops during the UP movement, before reaching
the limit switch.
• In case of overload during the UP movement the motor is switched
off. Make sure that no obstacles hinder the normal operation of the
winding tube.
• Tripping of thermal protection (in this case the motor does not
operate even for DOWN movements).
During the DOWN movement, the motor stops before
reaching the limit switch.
• In case of overload during the DOWN movement the motor is
switched off. Make sure that no obstacles hinder the normal opera-
tion of the winding tube.
• Tripping of thermal protection (in this case the motor does not
operate even for UP movements).
Both during the UP and DOWN movements the motor starts
up and runs for about 1 second.
• The encoder system does not work properly (contact the service
centre).
16
If the movement is reversed exchange the two motor phases.
At each UP command, the motor runs for a short time and
then stops.
• The limit switch and shutter position data are damaged; you need
to erase the data and re-program the limit switches.
The motor does not turn either up or down.
• Make sure that there is voltage between the common wire and the
electrical phase to be energized.
• Tripping of thermal protection, in this case wait for the motor to
cool.
Example
3s
3s
Example
3s
x3
www.stobag.com

Publicidad

Tabla de contenido
loading

Tabla de contenido