5) The resistance of the circuit to be measured appears on the screen. When the resistance of the measured circuit is less than about
20Ω, the built-in buzzer will sound.
When the resistance of the measured circuit is greater than 150Ω, the built-in buzzer will keep mute.
If the resistance of the measured circuit is between 20Ω and 150Ω, the buzzer may sound or keep mute.
If the resistance is greater than 400Ω, the "OL" appears on the screen.
Note:
Before the continuity test, ensure to switch off the power of the measured circuit and fully discharge all capacitors.

Diode test :

1) Connect the black probe to "
(Note: The polarity of the red test probe is "
2) Set the function switch to the "
3) Press the "
" button until the "
4) Connect the red test probe to the positive pole of the diode and the black test probe to the negative pole.
5) Read the approximation of the forward voltage drop of diode indicated on the screen. In case of wrong connection of the test
probes, "OL" will appear on the screen.
03015/03017
" jack and the red probe to "
".)
" position.
" symbol appears on the screen.