TO CONVERT APPLIANCE FOR USE WITH PROPANE GAS
Natural Gas To Propane Gas (LP) Conversion Instructions
WARNING
Propane Gas conversion is to be performed by a
Jenn-Air Authorized Service Contractor (or other
qualified
agency)
manufacturer's instructions and all codes and
requirements of the authority having jurisdiction.
Failure to follow instructions could result in serious
injury or property damage. The qualified agency
performing this work assumes responsibility for this
conversion.
Models - JGD8130 & JGD8345 Series
Manifold - Propane Gas pressure required - 10² W.C.
Incoming Propane Gas pressure required to appliance
pressure regulator - 11² - 12² W.C.
Propane Gas conversion orifice hoods are supplied with
these models.
Propane Gas input specified - JGD8130/JGD8345 -
33,000 BTU/hr / 51,000 BTU/hr.
BURNER
Left Rear (LR)
Left Front (LF)
Right Rear (RR)
Right Front (RF)
Center Rear (CR)
Center Front (CF)
in
accordance
with
BTU/hr
7,500
7,500
9,000
9,000
9,000
9,000
ELECTRICAL POWER AND GAS MUST BE
TURNED OFF PRIOR TO CONVERSION
the
LR
TIE DOWN
BOLT ON
EACH END
GREASE
CONTAINER
INCHES
ORIFICE
DIAMETER
#66
.0330
#66
.0330
#63
.0370
#63
.0370
#63
.0370
#63
.0370
6
WARNING
RR
CR
APPLIANCE PRESSURE
REGULATOR
WIRING BOX COVER
LF
JGD8345 (Shown)
COLOR
Zinc
Zinc
Blue
Blue
Blue
Blue
RF
CF
BLOWER CAN BE
SWIVELED 90_