Electric Specifications - GYS GYSPOT EXPERT 200 Manual Del Usario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
Translation of the original instructions
POWER SUPPLY (I P.51)
GYSPOT EXPERT 200
Supplied without plug. Single phase power supply 200V to 240V, 50-60Hz. Use of PH (1), NEUTRAL (2) and EARTH (PE).
Circuit breaker 30A delayed D curve.
GYSPOT EXPERT 400
400 V two phase power supply 50-60 Hz. Use of PH (1), PH 2 (2) and EARTH (PE). Circuit breaker 16A delayed D curve
or 16A fuses type aM.
NB : If the product trips the circuit breaker, please check that the correct fuse and an adequate circuit
breaker are being used.
PRODUCT SPECIFICATIONS
GYSPOT EXPERT

ELECTRIC SPECIFICATIONS

U
rated power supply voltage
1N
Frequency
U
rated no load voltage
20
Permanent power U
SP
Permanent supply current I
Maximal current of a permanent primary short circuit I
Maximal current of a secondary short circuit I
Permanent secondary current I
Type of welding current
THERMAL SPECIFICATIONS
Operating ambient temperature
Storage and transport operating ambient
OPERATING AND SETTINGS (III P.51)
1. Connect the machine to an appropriate power supply.
2. Connect the gun (or the guns) with the connectors.
The trigger gun has, in addition to the power connector, a trigger control connector. Connect the latter to
initiate using the trigger
3. Turn the breaker (1) to ON.
4. For the first use :
The indicators switch on for few seconds then the machine automatically switches in SYNERGIC mode (8) It indi-
cates :
- the tool (2) : set on 1 by defaut (star welding or use the hollow pulling clamp).
- the power level (3) : set on 5 by defaut (setting adapted for 0.8mm steel sheets).
To use the MANUAL mode (9), press on the button (10). The displays (3) and (4) light on :
- the power level (3) : set on 5 by defaut.
- the points time (4) : set on 5 by defaut (80 ms).
The SYNERGIC mode give to the user recommended factory settings for each tool used on a given sheet thic-
kness.
The MANUAL mode allows the user to choose his own types of settings, without the tool connected being taken
into account, by selecting the desired power and point time.
5. Depending the mode chosen, SYNERGIC or MANUAL, change the settings as follows :
- To change the tool, press on the arrows (5). - (Accessible in SYNERGIC mode only).
GYSPOT EXPERT 200 / 400
1p
1cc
2cc
2p
200
1~ 200V
1~ 208V
7.24V
7.53V
2.1kVA
9.05A
114A
116A
3150A
3200A
From +5°C to +40°C
From -25°C to +55°C
1~ 230V
1~ 240V
50/60Hz
8.33V
8.69V
127A
131A
3500A
3600A
250A
EN
400
2 ~ 400V
7.4V
1.9kVA
4.6A
60A
3200A
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Gyspot expert 400

Tabla de contenido