Niko 450-00064 Manual Del Usuario página 62

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 75
450-00064
feedback of settings or status: "Impulse mode", "Appliance 1 switched on", "Appliance
1 switched off"
Press ✱ to disconnect.
An alarm is passed to the selected number every 2min for as long as it is not confirmed. It
is repeated as often as set, regardless of the fact if the call has been taken or not.
3.2. Time out
If the telephone interface has been called into and no DTMF signals are received for 60s,
the interface releases the telephone line.
3.3. Power supply
The telephone interface can be powered with 12V (UPS). In this case, the power supply
has to be connected to terminals 12V (plus) and minus (see fig.1).
3.4. Behavior during power failure
All settings and switch statusses are permanently saved and are retrieved after a power
failure. If a power failure occurs during an alarm call, the alarm call is repeated after the
power is restored.
60
EN

Publicidad

Tabla de contenido
loading

Productos relacionados para Niko 450-00064

Tabla de contenido