GB
Specifications
Flow rate at 3 bar flow pressure:
- Spout
- Shower
Temperature
- Scalding protection possible by fitting a temperature limiter
(see replacement parts fold-out page II, order no. 46 375).
Installation
Installing hose guide, see fold-out page I, Figs. [1] and [2].
1. Remove protective sleeves (A1) and top plate (A), see
Fig. [1].
2. Attach hose guide (B) to top plate (A) using mounting and
sealing set (B1).
3. Fit escutcheon (B2) with adaptor (B3).
4. Shut off cartridge and open cold- and hot water connection.
5. Mount shower hose (C) with shower connection hose (C1)
from rough installation, see Fig. [2].
6. Slide spring (K) on shower hose (C) and push through hose
guide (B).
7. Screw taper nut (D) onto shower hose (C).
Locate top plate (A).
Install spout and handshower, see Fig. [3].
1. Place seal (E1) in taper nut (D) and fit handspray (E) to
taper nut (D).
2. Fit spout (G) with seal (G1) to the shank (H), tighten set
screw (J) with 3mm socket spanner and insert plug (J1).
Install escutcheon and lever, see Fig. [4].
1. Screw on cap (L).
2. Push on escutcheon mounting base (M) and secure with
screws (M1).
3. Grease inner seal (N1) and push on.
4. Clip in escutcheon (N).
5. Fit lever (O), secure by tightening the loosely fitted set
screw (O1) with 3mm socket spanner and insert plug (O2).
Grout the joint around the top plate with permanently
elastic material.
In this way, the inspection chamber will be accessible at any
time!
Operation
- Lever (O), see fold-out page III, Fig. [5]
- Diverter (U)
Pulling the lever will release water supply.
Water will emerge from the bath spout first.
approx. 26 l/min
Press diverter knob
approx. 9,4 l/min
Pull diverter knob
Flow is diverted automatically from shower outlet to bath spout
when the mixer is turned off.
Maintenance
Inspect and clean all parts, replace as necessary and grease
with special grease.
Shut off the hot and cold water supply!
I. Cartridge, see fold-out page III, Fig. [6].
1. Lever out plug (O2).
2. Loosen set screw (O1) with 3mm socket spanner and pull off
lever (O).
3. Pull off escutcheon (N) and O-ring (N1).
4. Screw out screws (M1) and detach ecsutcheon mounting
base (M).
5. Unscrew cap (L).
6. Remove screws (R) and detach complete cartridge (S).
7. Change either the complete cartridge (S).
Assemble in reverse order.
Observe the correct installation position.
Make sure that the cartridge seals engage in the grooves on
the housing. Fit screws (R) and tighten evenly and
alternately.
II. Shower hose, see Figs. [7] and [8].
1. Pull out shower hose (C) and remove handshower (E) from
taper nut (D), see Fig. [7].
2. Unscrew and remove adaptor (D1), see Fig. [8].
3. Pull out the shower hose (C) until shower connection
hose (C1) projects.
4. Secure the shower connection hose (C1) against slipping
down again.
5. Disconnect shower hose (C) and pull off spring (K).
Assemble in reverse order.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
For directions on the care of this mixer, please refer to the
accompanying Care Instructions.
= to divert flow from bath spout to
shower outlet
= to divert flow from shower outlet to
bath spout
2