Step 5: (Electric Dryer Only) Connect
Electrical Plug
For further assistance, refer to section on Electrical
Requirements.
IMPORTANT: Use only a new U.L. listed No. 10
(copper wire only) three conductor power supply
cord kit rated 240 Volts (minimum) 30 Amperes
and labeled as suitable for use in a clothes dryer.
1
4
THREE-WIRE
1
4
FOUR-WIRE
1
Typical Receptacle
2
Power Cord (Not supplied with dryer)
3
Strain Relief Nut
4
Strain Relief
Figure 12
NOTE: For more detailed information on
connecting three-wire or four-wire plugs, refer to
section on Electric Dryer Electrical Requirements.
NOTE: Four-wire cord is required for mobile
homes or where codes do not permit grounding
through neutral.
801504
2
3
D275I
2
D006I
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1
8
7
THREE-WIRE CONNECTION
1
7
1
3
11
FOUR-WIRE CONNECTION
NOTE: Dryer is shown with access cover removed for
illustration purposes only. NEVER operate the dryer
with access cover removed.
1
Ground Wire
2
Ground to Neutral Wire
3
Neutral Terminal
4
"L2" Terminal
5
Center Wire (Neutral)
6
Strain Relief (Not supplied with dryer)
7
Ground Screw
8
"L1" Terminal
9
Black Wire
10
White Wire (Neutral)
11
Red Wire
D679I
8
Figure 13
Installation
2
3
4
5
6
D679I
3
4
9
10
6
D680I
D680I
13