Setting The Production Setpoint; Boost Mode (Optional); (Optional); Pre-Configuration - Pool Technologie HYBRIDE UV/ULTRA LOW SALT Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
Water hardness (°f)
Water hardness (mg/l)
Reversal frequency
(hours)
1) Press and hold down the bottom key, until the message In is displayed.
2) Press the bottom key: the current setting flashes.
3) Select a reversal frequency using the top key.
4) Confirm with the bottom key: the display freezes for a moment.

7.6. Setting the production setpoint

Possible settings: from 00 to 10, in increments of 1.
Default setting: 10.
Select a production setpoint using the top key (no confirmation required).
Important note: It is not possible to measure the level of free chlorine in your pool.
You will have to proceed empirically to adjust the setpoint.
Do not take into account the chlorine values given in the maintenance manual.

7.7. Boost mode (optional)

Boost mode sets the production value to its maximum for 24 hours but can be stopped at any point. This function is
used when chlorine is urgently needed.
I
Boost mode cannot replace a conventional shock treatment in the case of water not fit for bathing.
Boost mode continues after powering off the electronics unit.
When the Boost mode terminates or stops, production continues according to the initial setpoint.
Switching on: Press the bottom button: the message bo appears.
Switching off: Press the top button.
7.8.
The socket marked
or an external control, or a cover position switch.

7.8.1. Pre-configuration

I
This configuration must be carried out.
1) Press and hold down the bottom key, until the message In is displayed.
2) Press on the top key x times until the message CG is displayed.
3) Press the bottom key (one of the following displays will flash).
4) Using the top key, move to position:
- CF, for connection to a flow sensor
- CE, for connection to an external control
- Co, for connection to a cover position switch
- oF to disable the
5) To confirm, press the bottom key: the display freezes for a moment.
0 to 2
2 to 5
0 to 20
20 to 50
16
14

(optional)

or
(depending on the model of the electronics unit) is used to connect a flow sensor,
socket (default setting).
5 to 8
8 to 12
12 to 20
80 to
50 to 80
120 to 200 200 to 400 400 to 600
120
12
10
20 to 40
40 to 60
8
6
4
> 60
> 600
2
10