Troubleshooting - LG LuV350P Serie Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Review this section to find do-it-yourself solutions for minor performance problems. Any service or repair needed, other than as described in this owner's
manual, should be performed through your local LGE service center.
WARNING
y Electrical shock and personal injury hazard.
y Always unplug the power cord from the electrical outlet before servicing. Failure to do so could result in electrical shock or personal
injury.
Problem
Vacuum cleaner will not run.
Vacuum unplugged at wall outlet.
Agitator motor overload protection.
Thermal protector activated.
Poor dirt pickup.
Full or clogged dust tank.
Dust tank improperly installed.
Clogged hose, wand or head.
Belt broken/not installed properly.
Agitator motor overload protection activated.
Hole in hose.
Worn agitator.
Agitator does not turn
Switch is off (unit is in floor mode).
Cleaner is in upright position.
Agitator motor overload protection is tripped (brush
is jammed).
Belt is broken.
Dust escapes the dust tank.
Dust tank improperly installed.
The dust tank lid is not closed.
The bottom plate is not latched.
Agitator on pet hair turbine
Dirty agitator or agitator supports.
tool will not run when
Obstruction in turbine air path.
attached.
Low suction from vacuum cleaner.
Accessory has no suction
Main wand still connected to body base.
when using with the handle.
Dust tank feels loose when
This is normal.
lifting by the carry handle.
Possible Causes

TROUBLESHOOTING

Solutions
Make sure cord is plugged into a functioning outlet.
Unplug the vacuum cleaner and check the agitator for
obstructions and reset the unit.
Allow the vacuum cleaner to cool down.
Empty dust tank and clean filters.
Make sure all dust tank components and filters are installed
correctly.
Check for clogs.
Check belt and replace if needed.
Unplug the vacuum cleaner and check the agitator for
obstructions. Press the reset button.
Inspect hose carefully. Replace if needed.
Contact service.
Turn on agitator power switch.
Press the body release and tilt until back.
Unplug the vacuum cleaner and check the agitator for
obstructions and reset the unit.
Replace belt.
Make sure all dust tank components and filters are installed
correctly.
Check the dust tank lid.
Make sure the bottom plate is closed and latched.
Clean the inside of the pet hair turbine tool.
Clean the inside of the pet hair turbine tool.
Check for clogs.
Remove wand.
The vacuum is designed like this to prevent the tank from
separating
19

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido