MONOBLOC 100L
10.4. Cleaning Filter of Reduction Valve
To periodically clean the filter of the reduction valve, you should:
• Shut off the water supply.
• Turn anti-clockwise until you remove tension from the spring
• Remove the handle
• Remove filter and clean
10.5. Condensate Circuit
Make sure you check the condensate draining system and the drip tray in the maintenance and cleaning
service routines of your system. Clean the drip tray used as it may contain accumulated dust from the out-
side, which may obstruct the condensates drainage holes. Make sure the holes and the condensate outlet
pipe are not obstructed.
10.6. Cleaning the Air Circuit
Make sure the air inlet filters are not obstructed, if applicable. Inspect at least once a year.
The evaporator may have deposited dust. Clean it also, but be careful with its fins.
The evaporator's fins are quite thin, so there is additional risk of injuries.
Take care not to damage them.
WARNING
10.7. Safety Thermostat
The safety thermostat is deactivated whenever there is an anomaly in the system, so every time you plan
to activate it, find out what happened that caused it to change its status mode.
If you were not able to determine what happened and it is still deactivated, contact customer service to
have your problem solved.