1. CONNECT FLUSHOMETER
A.
A. Remove mud plate and save for later use - DO NOT DISCARD
PRIOR TO CONNECTING, MAKE SURE SUPPLY LINES ARE FLUSHED OUT- DEBRIS CAN CAUSE VALVE TO MALFUNCTION OR DAMAGE CAN
ENSUE
B. Connect inlet pipe to top of flushometer, tighten securely with Fixed jaw wrench.Connect fixture flush connection to bottom of flushometer, tighten
securely
C. Reinstall mud plate to valve. Finish the wall
D. Remove mud plate and discard
NOTE. Wall plate opening must be minimum of 4" x 4" (102 x 102 mm) to maximum of
2. ADJUST CONTROL FLOW
If supply line was flushed and is clean of debris, proceed
to step P.
If supply line was not previously flushed, follow steps A-Q.
Valve is shipped with the flow adjustment turned off.
A. Ensure activation assembly is turned fully clockwise to make sure water
is off
B. Push plunger screw in center to relieve pressure
C. Remove orange safety ring by squeezing pins together
D. Grab with fingers or pliers and pull out activation assembly. Do not
rotate to avoid turning water on!
E. Remove piston by pulling it straight out
F. Reinstall activation assembly and press until fully seated
G. Reinstall orange safety ring securely
H. Using tool, (Screwdriver or wrench) turn activation assembly counter
clockwise slowly to open flow of water to flush the lines- careful not to
overflow the fixture
I. Once lines are flushed clear, turn activation assembly clockwise to shut
water flow off
J. Push button/plunger in center to relieve pressure
K. Remove orange safety ring by squeezing pins together
L. Grab with fingers or pliers and pull out activation assembly.
Do not rotate to avoid turning water on!
M.Reinstall piston- insert colored end first until fully seated
N. Reinstall activation assembly and press until fully seated
O. Reinstall orange safety ring securely
P. Using tool (screwdriver or wrench), turn activation assembly slowly
counterclockwise to open flow of water
Q. Push plunger screw to activate flush and adjust water flow as needed
by rotating activation assembly (clockwise to lessen flow and counter
clock wise to increase flow)
C.
B.
2
D.
4.5" x 4.5" (114 mm x 114 mm)
A.
C.
E.
B.
D.
H.