5.1 Programming Mode Parameter List
PID - Proportional Control Parameter
This parameter value can be adjusted form 0.0 to 100.0
PID - Integral Parameter
This parameter value can be adjusted form 0 to 3600.
PID - Derivative Parameter
This parameter value can be adjusted form 0.0 to 999.9.
PID - Period Parameter
This parameter value can be adjusted form 1 to 50 second.
Hysteresis Parameter for Temperature ( Default = 0.1 )
From 1 to 10°C , PT-100 (0°C, 100°C)
From 1 to 18°F, PT-100 (32°F, 212°F)
From 0.1 to 10.0°C ,PT-100(0.0°C,100.0°C)
From 0.1 to 18.0°F ,PT-100(32.0°F,212.0°F)
In ON/OFF control algorithm,
temperature value is tried to keep equal
to set value by opening or closing the last
control element. ON/OFF controlled
system, temperature value oscillates
continuously. Temperature value's
oscillation period or amplitude around set
value changes according to controlled
system. For reducing oscillation period of
temperature value, a threshold zone is
formed below or around set value and
this zone is named hysteresis.
Minimum Temperature Set Value Parameter ( Default = 10.0°C)
Temperature set value can not be lower than this value. This parameter value can be
adjusted from minimum value of device scale to maximum temperature set value
parameter
Maximum Temperature Set Value Parameter ( Default = 40.0 °C )
Temperature set value can not be greater than this value.
This parameter value can be adjusted from minimum temperature set value parameter
to maximum value of the device scale.
Temperature Sensor Offset Parameter ( Default = 0.0 )
From -10 to 10°C , PT-100 (0°C, 100°C)
From -18 to 18°F, PT-100 (32°F, 212°F)
From -10.0 to 10.0°C ,PT-100(0.0°C,100.0°C)
From -18.0 to18.0°F ,PT-100(32.0°F,212.0°F)
Time of Automatic Egg Tray Rotator ( Default = 00:00 )
This parameter value can be adjusted form 00:00 to 99:59 minute/second.
Repeat cycle of Automatic Egg Tray Rotator ( Default = 00:00 )
This parameter value can be adjusted form 00:00 to 24:00 hour/minute.
Alarm or
Note : if Lou parameter value is 3, Hdt and HdP parameters are observed.
Time of Humidifier ( Default = 00:00 )
This parameter value can be adjusted form 00:00 to 99:00 minute/second.
( Default = 300 )
( Default = 60.0 )
( Default = 1 )
Humidifier
Output Function Selection Parameter
Alarm is inactive
Alarm-Temperature sensor failures.
Alarm-Temperature or Temperature sensor failures.
Humidifier Output
( Default = 1.0 )
Temperature
HSt
Set
Control
Output
ON
OFF
HSt
Time
Time
( Default = 3 )
9