If there is a great amount of powder in the air,
the filter must be cleaned once a week, or even
every day. Pull the front panel out and clean the
filter. If necessary, you may slightly knock all
over the filter, use a vacuum cleaner to remove
bigger pieces of dirt or even wash the filter in
warm clean water (≤40% with some neutral de-
tergents) and then dry it.
6. TROUBLE - SHOOTING
►
►
UNIT DOES NOT WORK
► Analysis
1.Power cut
2.Switch off
3.Unplugged
4.Fuse melted
5.Tank full
► Solution
1.Power on
2.Switch on
3.Plug on
4.Exchange fuse
5.Empty the tank and replace it
DEHUMIDIFIES IN INADEQUATELY
► Analysis
1.Filter choked by dirt
2.Some barrier
in air inlet or outlet
3.Door or windows open
4.Refrigerant leakage
► Solution
1.Clean the filter
2.Remove the barrier
3.Close the door and windows and
seclude from the sunshine
4.Contact the manufacturer or seller
WATER LEAKAGE
► Analysis
1.The unit is inclined
2.Drainer choked
► Solution
1.Adjust the unit to be stable
2.Pull out the panel and remove the barrier
STRANGE NOISE
► Analysis
1. Until instable
2. Filter choked
► Solution
1.Place the unit stably
2.Clean the filter
► When above malfunctions occur and they
could not be removed, please contact the sup-
plier or seller, do not disassemble the machine
yourself.
► When the unit starts or stops running, it makes
certain noises of refrigerating circulation, which
should not be considered as a malfunction.
► Hot air coming from the air outlet is normal.
INSTRUCTION
CODES:
The unit analyzes malfunction automatically and
displays the code on the humidity window.
MALFUNCTION DISPLAY
► Sensor of humidity
MALFUNCTION DISPLAY
► Sensor of refrigeration pipeline
►
7. ACCESSORIES
►
The dehumidifier is adjusted to work with the
water pump installed in place of the water tank.
The pump socket is located inside the tank hole.
CAUTION: The unit contains substances
and components dangerous for the environ-
ment (electronic components, refrigerant gas
and oils). At the end of its useful life, in the
event of dismantling the unit, the operation
must be carried out by specialised refrigerat-
ing personnel.
The unit must be sent to specific special-
ised centres for the collection and disposal of
equipment containing dangerous substanc-
es. The refrigerant fluid and the lubricating
oil contained in the circuit must be recovered,
in accordance with the regulations in force in
your country.