PROPANE CONSTRUCTION HEATER
USA 8-Hr Time weighted average
(OSHA 29 CFR 1926.55 App A)
CO
50 ppm
CO
5000 ppm
2
NO
2
USA – Ceiling Limit
(Short Term Exposure Limit = 15 minutes)
CO
CO
2
NO
5 ppm
2
• Ensure that the flow of combustion and ventilation air exchange cannot become obstructed.
• As the building 'tightens up' during the construction phases ventilation may need to be increased.
Model No.
INPUT RATING
TYPE OF GAS
GAS SUPPLY PRESSURE TO REGULATOR MAXIMUM
MINIMUM (FOR PURPOSE OF INPUT ADJUSTMENT)
MANIFOLD PRESSURE
GAS CONSUMPTION (Lb/Hr)
GAS CONSUMPTION (Kg/Hr)
ELECTRICAL INPUT
AMPERAGE
SPARK GAP
SIZE (LxWxH)
SPECIFICATIONS
LOAD
IGNITION
Canada 8-hr time weighted average
WorkSafe BC OHS Guidelines Part 5.1
and Ontario Workplaces Reg 833
25 ppm
5000 ppm
3 ppm (Reg 833)
Canada STEL (15 minutes Reg 833/1 hour WSBC)
WorkSafe BC OHS Guidelines Part 5.1 and Ontario
Workplaces Reg 833
100 ppm
15000 ppm (WSBC)
30000 ppm (Reg 833)
1.0 ppm (WorkSafeBC)
5.0 ppm (Reg 833)
FA 60 Series
36000 BTU/hr , 60000 BTU/hr
PROPANE
BOTTLE PRESSURE
25 PSI / 172 KPa
5 PSI
High-2.78 Low-1.67
High-1.26 Low-0.76
120 V , 60 Hz
0.22 AMPS
ELECTRONIC SPARK
4 mm (0.157")
43.9 cm x 19.8 cm x 35.1 cm
(17.3" x 7.8" x 13.8")
5
FA 125 Series
70000 BTU/hr , 125000 BTU/hr
PROPANE
BOTTLE PRESSURE
25 PSI / 172 KPa
5 PSI
High 5.79 Low-3.29
High 2.63 Low-1.49
120 V , 60 Hz
0.35 AMPS
ELECTRONIC SPARK
4 mm (0.157")
56.9 cm x 22.1 cm x 43.7 cm
(22.4" x 8.7" x 17.2")