9 - CONTROL PANEL
9.1 - DISPLAY
When power is on, the control unit checks that display correctly
operates by switching on all segments for 1.5 sec.
Pr I.0
Firmware version, e.g.
1.5 sec.
Panel will be viewed upon completion of this test.
CLOSED CONTACT
OPENED CONTACT
START
PHOTOCELL
STOP / EDGE
OK
PLEASE NOTE: if the panel is off, the control unit should be
in ENERGY SAVING mode; press the OK key to turn it on.
The control panel (in stand-by) displays the physical status of the
terminal board contacts, of the realignment switch and of the
setup keys: if the
upper vertical segment is on, the contact is closed; if the lower
vertical segment is on, the contact is open (the above picture
shows an instance where the inputs have all been correctly
connected).
The encoder segments flash alternately when the motor is
running, indicating that the device is working correctly.
Points being among display digits show the status of
programming push-buttons: as soon as a push-button is pressed,
its relevant point turns on.
The arrow to the left of the display shows the status of the START
input. The arrow lights up when the input is closed.
The arrows on the display right side show the door status:
•
The highest arrow turns on when the door is into its opening
phase.
•
The central arrow shows that the door is on pause.
If it blinks, it means that the time countdown for the
automatic closing has been activated.
•
The lowest arrow blinks when the door is into its closing
phase.
8.8.8.8
, will be viewed in the following
OPENING IN PROGRESS
PAUSE (DOOR OPENED)
CLOSING IN PROGRESS
ENCODER
SWITCH
9.2 - USE OF THE KEYS FOR
PROGRAMMING
The control unit functions and times are programmed by means
of a special configuration menu, which can be accessed and
explored by using the 3 keys,
.
control unit display.
ATTENTION: Outside the configuration menu, by pressing
h
the
keys you will enable the OPENING phase and by
i
pressing the
The main programming menus of the control unit are shown in
the next pages.
To go through the menus use the three keys
according to the following chart:
- 36 -
h
i
,
and OK, located under the the
key you will enable the CLOSING phase.
h
Press and release the push-button OK
Keep pressed the push-button OK for 2 seconds
Release the push-button OK
Press and release the push-button
Press and release the push-button
i
,
and OK
h
i