Gas Connection - ELICA NT-FLAME-GR-DO Montaje Y Modo De Empleo

Ocultar thumbs Ver también para NT-FLAME-GR-DO:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 122
● Please note! Before reconnecting the
circuit to the mains power supply, make
sure that it is working correctly, always
check that the power cable is correctly
installed.
interconnection cable must be replaced
by the authorised technical support
service or by a person with similar
qualifications.

3.2 Gas connection

● The installation must be performed by
professionally qualified personnel familiar
with the applicable installation and safety
regulations. ● Connect the device to the
cylinder or gas supply in accordance with
the provisions of the standards in force,
making sure in advance that the
equipment is pre-configured for the type
of gas available.
● If not, refer to: "Adaptation to
different types of gas". ● Check also
that the supply pressure falls within the
values in the table: "Characteristics of
gas burners". ● Rigid/semi-rigid metal
connection ● Make the connection with
metal fittings and pipes (also flexible) to
avoid straining the internal parts of the
appliance. ● When installing flexible
pipes, make sure that, when fully
extended, their length does not exceed 2
metres. ● Only use pipes that comply
with the national standards in force. ●
N.B. - Once the installation is complete,
check that the entire connection system
is properly sealed with a soapy solution.
Never use a flame to perform this check.
● Adaptation to different types of gas
Please
note!
● To adapt the appliance to a type of gas
other than that for which it is designed
(as indicated on the label fixed to the
lower part of the hob or the packaging),
The
the burner nozzles must be replaced by
performing the following operations: ● 1 -
remove the stove top grids and remove
the burners from their slots ● 2 - unscrew
the nozzles, using a 7mm socket wrench
and replace them with ones suitable for
the new type of gas (see table
"Characteristics of gas burners") ● 3 -
reassemble the parts following the steps
in reverse order ● Warning! At the end
of the operation, replace the old
calibration label with the one for the new
gas used.FIG.A0.
● Minimum adjustment ● For minimum
adjustment: ● 1 - turn the tap to the
minimum setting ● 2- remove the knob
and adjust the screw located inside or
next to the valve shaft, with a suitable
screwdriver, until a small regular flame is
obtained FIG.A01 ● 3 - check that by
turning the knob quickly, from maximum
to minimum, the burners do not turn off ●
4 - if the safety device fails
(thermocouple), with the burners on
minimum setting, increase the minimum
flow rate by adjusting the relevant screw.
● 5 - once the adjustment has been
made, re-seal the seals on the by-pass
with sealing wax or equivalent materials
● In the case of liquid gases (e.g. LPG),
the adjustment screw must be screwed in
completely. ● Warning! At the end of the
operation, replace the old calibration
label with the one for the new gas used.
● Warning! If the pressure of the gas
70

Publicidad

Tabla de contenido
loading

Tabla de contenido