5. Stack the tray on top of the lower rack and place the lid on top of the tray. Ensure
that the lid fits securely on the tray without any gaps.
6. Plug the power cord into an electrical outlet and press the Power Button.
NOTE: When the sterilizer is turned on, the appliance will beep and the indicator
above the power button will light up. Choose your desired function following the
instructions on pages 4 & 5.
STERILIZE ONLY FUNCTION:
7. Complete steps 1 – 6 outlined on page 3 & 4, then press the "Sterilize Only" button
once. The appliance will beep one time and the sterilization cycle will start.
8. When the sterilization cycle is complete, the appliance will beep five times and
switch off automatically.
NOTE: Wait 10 minutes to allow parts to cool before removing anything from the unit.
NOTE: This cycle lasts approximately 9 minutes but may vary by the amount of
water you add, the number of items to be sterilized and other environmental
factors. If insufficient water is added, the appliance will beep five times to remind
you the sterilization time may be insufficient to disinfect the bottles and accessories,
and the indicator light will flash. Wait 10 minutes to allow unit to cool, then
press the power button to reset the appliance and repeat steps (7) and (8) above.
Should no action be taken, the indicator light will flash for 2 hours and then the
appliance will automatically turn off.
CAUTION:
Do not touch the lid, tray, or lower rack when sterilization is in process,
as these surfaces get hot.
DRY ONLY FUNCTION:
9. Press the power button, then press the "Dry Only" button once. The appliance will
beep one time and the drying cycle will start.
10. When the drying cycle is complete, the appliance will beep five times and switch
off automatically.
NOTE: This cycle lasts approximately 45 minutes.
AUTOMATIC STERILIZE/DRY FUNCTION:
11. Complete steps 1 – 6 outlined on page 3 & 4, then press the "Automatic Sterilize/Dry"
button once. The appliance will beep one time and the sterilization cycle will start.
12. When the sterilization cycle is complete, the drying cycle will begin automatically.
The drying cycle lasts approximately 45 mins.
CAUTION:
As the unit switches from the sterilization to the drying cycle, it is
expected to see a large initial release of steam as the fan turns on. Keep a safe
distance from the unit while this cycle is in process.