Set dimming level of your choice:
- Hold button down until LED
flashes.
- Keep button pressed, the system will slowly run
through dimmer range from 0 – 50%.
- Release button when chosen setting is reached.
The LED will now continue flashing for about 5 sec.
This period may be used for optimising the dimmer
setting.
Manual override function
If a mains switch is installed in the mains supply lead,
the SensorLight provides the following functions in addi-
tion to just being able to switch it 'ON' and OFF:
Sensor operation
1) Switch light ON:
Turn switch 'OFF' and 'ON' once.
Light stays 'ON' for the period selected.
2) Switch light OFF:
Turn switch 'OFF' and 'ON' once.
The light goes out or switches over to sensor mode.
Manual override
1) Activate manual override:
Turn switch 'OFF' and 'ON' twice. The light is set to stay
'ON' for 4 hours (red LED
lights up). Then it returns
automatically to sensor mode (red LED
'OFF').
2) Deactivate manual override:
Turn switch 'OFF' and 'ON' once. The light goes out or
switches over to sensor mode.
Important:
The switch should be actuated in rapid succession
(in the 0.5 – 1 sec. range).
Reset function
The light can be returned to its original settings at any
time (daylight operation 2000 lux, 'ON' time 5 sec-
onds and basic lighting level 'OFF').
To do this, hold all three buttons down at the same
time until the LED comes 'ON' and goes out again
(approx. 5 sec.).
Soft light start
The SensorLight features a soft light start function.
This means that when the light is switched 'ON', it
does not go directly to maximum output but gradually
increases brightness to 100 % over the space of one
second. Brightness is also gradually reduced when
the light is switched 'OFF'.
Basic reach setting
The sensor lens is divided into two detection zones.
One half provides a max. reach of 5 m, the other half
a max. reach of 12 m (when installed at a height of
approx. 2 m). After fitting the lens (firmly clip lens into
the groove provided), a small arrow marks the max.
reach of 12 m or 5 m selected (arrow left = 5 metres,
arrow right = 12 metres).
Using a screwdriver, the lens can be unclipped from
the groove at the side and re-positioned for the reach
you require.
Precision adjustment
using shrouds
Shrouds may be used to define the detection zone
exactly as you require in order, for example, to blank
out or specifically target paths or neighbouring prem-
ises. The shrouds can be divided or cut with a pair of
scissors along the vertical and horizontal grooves.
They can be clipped into the top channel around the
centre of the lens. Finally, they are secured in place
after fitting the designer-style trim with glass shade
,
(Fig.
shows examples of how you can reduce
the angle of coverage and shorten reach.)
Operation / Maintenance
The SensorLight is suitable for switching ON light
automatically. Weather conditions may affect the way
the SensorLight functions. Strong gusts of wind,
snow, rain or hail may cause the light to come ON
when it is not wanted because the sensor is unable to
distinguish sudden changes of temperature from
sources of heat. The detector lens may be cleaned
with a damp cloth if it gets dirty (do not use cleaning
agents).
Declaration of conformity
This product complies with
- Low Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
- 10 -

Troubleshooting

Malfunction
SensorLight without power
SensorLight will not switch 'ON'
SensorLight will not switch 'OFF'
SensorLight switches 'ON' when it
should not
.
Change in SensorLight reach
LED 'ON' all the time although
manual override is not selected
LEDs flickering
Declaration of Guarantee
All rights are based on our guarantee period. We
guarantee that your STEINEL Professional sensor
product will remain in perfect condition and proper
working order for a period of 5 years. We guarantee
that this product is free from material, manufacturing
and design flaws. In addition, we guarantee that all
electronic components and cables function in the
proper manner and that all materials used and their
surfaces are without defects.
Making Claims
If you wish to make a claim, please send your prod-
uct complete and carriage paid with the original
receipt of purchase, which must show the date of
purchase and product designation, either to your
retailer or directly to us at STEINEL (UK) Limited,
25 Manasty Road, Axis Park, Orton Southgate,
Peterborough, PE2 6UP. For this reason, we recom-
Cause
Remedy
n Fuse faulty, not switched 'ON',
n Fit new fuse; switch 'ON' mains
break in wiring
switch; check wiring with volt-
age tester
n Short circuit
n Check connections
n Twilight setting in night-time
n Reset (button
mode during daytime operation
n Power switch 'OFF'
n Switch 'ON'
n Fuse faulty
n New fuse, check connection
if necessary
n Detection zone not properly
n Re-adjust
targeted
n Internal electrical fuse has been
n Switch SensorLight 'OFF' and
activated (LED 'ON' all the time)
back 'ON' again after 5 sec.
n Continued movement within the
n Check detection zone and
detection zone
re-adjust if necessary
n Basic lighting level > 0 %
n Set basic lighting level to 0 %
(button
n Wind is moving trees and
n Change detection zone
bushes in the detection zone
n Cars in the street are being
n Change detection zone
detected
n Sunlight shining on the lens
n Mount sensor in a sheltered
place or change detection zone
n Sudden temperature changes
n Change detection zone, change
due to weather (wind, rain,
site of installation
snow) or air expelled from fans,
open windows
n Lens not pressed firmly enough
n Press lens into groove
into groove
n Differing ambient temperatures
n Use shrouds to define detection
zone precisely
n Internal fuse activated
n Switch SensorLight 'OFF' and
back 'ON' again after 5 sec.
n Local power grid
n see note on page 9
mend that you keep your receipt of purchase in a
safe place until the guarantee period expires.
STEINEL shall assume no liability for the costs or
risks involved in returning a product.
For information on making claims under the
terms of the guarantee, please go to
www.steinel-professional.de/garantie
If you have a guarantee claim or
would like to ask any question
regarding your product, you are
welcome to call us at any time on
our service hotline 01733 366700.
- 11 -
)
)

Publicidad

Tabla de contenido
loading

Tabla de contenido